Echo-Planar Cardiac MRI using Parallel Imaging

نویسندگان

  • Krishna S. Nayak
  • Peter Kellman
چکیده

Since it’s original proposal by Mansfield et al. in 1977 [1], echo-planar imaging (EPI) has had a key role in the evolution of cardiac MRI. EPI involves the rapid acqusition of k-space data in a raster-like fashion, requiring a fewer number of excitations compared to conventional 2DFT imaging. This is crucial in cardiac imaging as respiratory and cardiac motion places high demands on imaging speed. EPI has been used for a wide array of cardiac applications including the imaging of myocardial function, perfusion, and coronary arteries, and real-time localization. EPI can be used as a single-shot technique or can be used with multiple excitations with a variety of ordering schemes (e.g. sequential, interleaved, center-out, top-down). It can also be used in a ’fly-back’ mode which involves traversing k-space in the same direction during each echo [2]. There are many subtle variations of EPI, each with its own advantages and disadvantages. Limitations of EPI are well-known [3–6] and include:

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improvements in parallel imaging accelerated functional MRI using multiecho echo-planar imaging.

Multiecho echo-planar imaging (EPI) was implemented for blood-oxygenation-level-dependent functional MRI at 1.5 T and compared to single-echo EPI with and without parallel imaging acceleration. A time-normalized breath-hold task using a block design functional MRI protocol was carried out in combination with up to four echo trains per excitation and parallel imaging acceleration factors R = 1-3...

متن کامل

Rapid T1 mapping of mouse myocardium with saturation recovery Look-Locker method.

Dynamic contrast-enhanced MRI using gadolinium or manganese provides unique characterization of myocardium and its pathology. In this study, an electrocardiography (ECG) triggered saturation recovery Look-Locker method was developed and validated for fast cardiac T(1) mapping in small animal models. By sampling the initial portion of the longitudinal magnetization recovery curve, high temporal ...

متن کامل

Parallel magnetic resonance imaging.

Parallel imaging has been the single biggest innovation in magnetic resonance imaging in the last decade. The use of multiple receiver coils to augment the time consuming Fourier encoding has reduced acquisition times significantly. This increase in speed comes at a time when other approaches to acquisition time reduction were reaching engineering and human limits. A brief summary of spatial en...

متن کامل

Diffusion imaging in humans at 7T using readout-segmented EPI and GRAPPA.

Anatomical MRI studies at 7T have demonstrated the ability to provide high-quality images of human tissue in vivo. However, diffusion-weighted imaging at 7T is limited by the increased level of artifact associated with standard, single-shot, echo-planar imaging, even when parallel imaging techniques such as generalized autocalibrating partially parallel acquisitions (GRAPPA) are used to reduce ...

متن کامل

Parallel imaging techniques in functional MRI.

Originally developed for increased scanning velocity in cardiac imaging, parallel imaging (PI) techniques have recently also been applied for the reduction of artifacts in single-shot techniques. In functional brain imaging (fMRI) techniques, PI has been used for several purposes. It has been applied to reduce the distortions caused by the length of the echo-planar imaging readout, diminution o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006