Ijraet a Flexible Harmonic Control Approach through Current- Controlled Dg–grid Interfacing with Closed-loop Power Control Using Fuzzy Logic Controller

نویسندگان

  • KANDALA GANGA
  • SAMPATH
  • K.NAGARAJU
چکیده

The increasing application of nonlinear hundreds might cause distribution system power quality problems. so as to utilize distributed generation (DG) unit interfacing converters to actively compensate harmonics, this paper proposes associate increased current management approach, that seamlessly integrates system harmonic mitigation capabilities with the first weight unit power generation operate. because the projected current controllers has 2 well decoupled management branches to severally control basic and harmonic weight unit currents, native nonlinear load harmonic current detection and distribution system harmonic voltage detection don't seem to be necessary for the projected harmonic compensation technique. Moreover, a closed-loop power management theme is used to directly derive the elemental current reference while not mistreatment any phase-locked loops (PLL). The projected power management theme effectively eliminates the impacts of steady-state basic current chase errors within the weight unit units. Thus, associate correct power management is accomplished even once the harmonic compensation functions area unit activated. Additionally, this paper conjointly in brief discusses the performance of the projected technique once weight unit is connected to a grid with frequency deviation. Simulated and experimental results from a single-phase weight unit validate the correctness of the projected strategies with fuzzy logic controller.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Power Quality Improvement from Grid Connected Renewable Energy Sources At Distribution Level Using Fuzzy Logic Controller

Harmonic pollution of the power supply system has risen significantly in recent years due primarily to an increase of non-linear loads connected to the utility through residential, commercial and industrial customers. Power supply voltages become distorted due to the high level of undesired harmonic current drawn from the utility. Additionally, drops in fundamental voltage are caused by the int...

متن کامل

Fuzzy-Decision-Making Predictive Power Control Approach to On-Grid Photovoltaic Panel

In this paper, a voltage-current mode controller is proposed to adjust both the input current and DC voltage of a boost-inverter in order to improve the performance of the photovoltaic (PV). The proposed system is based on fuzzy-making-decision predictive voltage-current controller (FPVCC). The simulation results show that in case of using the proposed FPVCC, the input current of a PV array is ...

متن کامل

Mitigation of Harmonics for Grid-inter Connected DG system With Closed-Loop Power Control technique

The proposed system presents power-control strategies of a grid-connected hybrid generation system with versatile power transfer. This hybrid system allows maximum utilization of freely available renewable energy sources like wind and photovoltaic energies. For this, an adaptive MPPT algorithm along with standard perturbs and observes method will be used for the system. Also, this configuration...

متن کامل

Design and Implementation of Fuzzy Logic Based Voltage Control of A 3- Phase Power Converter

This project presents the operation of a distributed generation (DG) system driven by a dcdc step-up converter and a dc-ac voltage source inverter (VSI) interfaced with the power grid by Fuzzy Controller. To create a stable mode when different kinds of loads are connected locally or when working under contingency, the step-up converter must regulate the dc link voltage, allowing the VSI to stab...

متن کامل

Power Quality Improvement for Grid Connected Wind Energy System Using Upfc

In this paper, a cascaded current–voltage control strategy is proposed for inverters to simultaneously improve the power quality of the inverter local load voltage and the current exchanged with the grid. It also enables seamless transfer of the operation mode from standalone to grid-connected or vice versa. The control scheme includes an inner voltage loop and an outer current loop, with both ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015