Efficacy of the RADPAD Protection Drape in Reducing Operators' Radiation Exposure in the Catheterization Laboratory: A Sham-Controlled Randomized Trial.
نویسندگان
چکیده
BACKGROUND Interventional cardiologists are increasingly exposed to radiation-induced diseases like cataract and the stochastic risk of left-sided brain tumors. The RADPAD is a sterile, disposable, lead-free shield placed on the patient with the aim to minimize operator-received scatter radiation. The objective of the trial was to examine the RADPAD's efficacy in a real-world situation. METHODS AND RESULTS In the current, double-blind, sham-controlled, all-comer trial, patients undergoing diagnostic catheterization or percutaneous coronary interventions were randomized in a 1:1:1 ratio to a radiation absorbing shield (RADPAD), standard treatment (NOPAD), or a sham shield (SHAMPAD). The sham shield allowed testing for shield-induced radiation behavior. The primary outcome was the difference in relative exposure of the primary operator between the RADPAD and NOPAD arms and was defined as the ratio between operator's exposure (E in µSv) and patient exposure (dose area product in mGy·cm2), measured per procedure. A total of 766 consecutive coronary procedures were randomized to the use of RADPAD (N=255), NOPAD (N=255), or SHAMPAD (N=256). The use of RADPAD was associated with a 20% reduction in relative operator exposure compared with that of NOPAD (P=0.01) and a 44% relative exposure reduction compared with the use of a SHAMPAD (P<0.001). Use of the SHAMPAD was associated with a 43% higher relative radiation exposure than procedures with NOPAD (P=0.009). CONCLUSIONS In clinical daily practice, the standard use of the RADPAD radiation shield reduced operator radiation exposure compared with procedures with NOPAD or SHAMPAD. This study supports the routine use of RADPAD in the catheterization laboratory. CLINICAL TRIAL REGISTRATION URL: https://www.clinicaltrials.gov. Unique identifier: NCT03139968.
منابع مشابه
A novel radiation protection drape reduces radiation exposure during fluoroscopy guided electrophysiology procedures.
OBJECTIVE The purpose of this study was to evaluate a novel disposable lead-free radiation protection drape for decreasing radiation scatter during electrophysiology procedures. BACKGROUND In recent years, there has been an exponential increase in the number of electrophysiology (EP) procedures exposing patients, operators and laboratory staff to higher radiation doses. METHODS The RADPAD w...
متن کاملRadiation Dose Reduction during Radial Cardiac Catheterization: Evaluation of a Dedicated Radial Angiography Absorption Shielding Drape
Objectives. Radiation scatter protection shield drapes have been designed with the goal of decreasing radiation dose to the operators during transfemoral catheterization. We sought to investigate the impact on operator radiation exposure of various shielding drapes specifically designed for the radial approach. Background. Radial access for cardiac catheterization has increased due to improved ...
متن کاملEffect of Rosa aromatherapy on anxiety before cardiac catheterization: A randomized controlled trial
Background and Objectives: Most patients experience moderate to severe anxiety before cardiac catheterization. This study aimed to investigate the effect of Rosa aromatherapy on anxiety before cardiac catheterization. Methods: In this randomized controlled trial, 60 patients who met the inclusion criteria were conveniently sampled and randomly allocated to the experimental and control groups. P...
متن کاملThe Effect of Listening to the Voice of Quran on Anxiety before Cardiac Catheterization: A Randomized Controlled Trial
Background and objectives: Patients experience moderate to high level of anxiety before cardiac catheterization. This study aimed to investigate the effect of voice of Quran on anxiety before cardiac catheterization. Methods: In this randomized controlled trial, 60 patients who met the inclusion criteria were conveniently sampled and randomly allocated to the experimental and control groups. In...
متن کاملEfficacy of Topical Alpha Ointment (Containing Natural Henna) Compared to Topical Hydrocortisone (1%) in the Healing of Radiation-Induced Dermatitis in Patients with Breast Cancer: A Randomized Controlled Clinical Trial
Background: This two-arm, randomized clinical study aimed to compare efficacy between topical Alpha ointment and topical hydrocortisone cream (1%) in the healing of radiation-induced dermatitis in breast cancer patients. Methods: The inclusion criteria comprised newly pathologically proven, locally advanced breast cancer (treated with modified radical mastectomy followed by sequential adjuvant ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Circulation. Cardiovascular interventions
دوره 10 11 شماره
صفحات -
تاریخ انتشار 2017