Comparison of corneal flap thickness using a FS200 femtosecond laser and a moria SBK microkeratome.
نویسندگان
چکیده
AIM To evaluate differences in flap thickness resulting from use of an Alcon Wavelight FS200 femtosecond laser and a MORIA SBK microkeratome when making a 110-µm-thick corneal flap and to identify the potential factors that affect corneal flap thickness. METHODS A prospective case study was performed on 120 eyes of 60 patients who were divided into two groups for LASIK, each group consisting of 60 eyes (30 patients). The corneal flaps were created using an Alcon Wavelight FS200 femtosecond laser or a MORIA SBK microkeratome. The central corneal flap thickness was calculated by subtraction pachymetry. Age, central corneal thickness (CCT), spherical equivalent refraction, mean keratometry, and corneal diameter were recorded preoperatively for analysis. RESULTS Cutting of all flaps was easily performed without intraoperative complications. In the Alcon Wavelight FS200 femtosecond laser group, the mean right and left corneal flap thicknesses were 114.0±6.6 µm (range: 98-126) and 111.4±7.6 µm (range: 98-122), respectively. The difference (2.6±9.1 µm) in the corneal flap thickness between the right and left eyes was not significant (t=1.59, P=0.12). Stepwise regression analysis indicated that the resulting corneal flap thickness was unrelated to the patient's age, preoperative CCT, spherical equivalent refraction, mean keratometry, or corneal diameter. In the MORIA SBK microkeratome group, the mean right and left corneal flap thicknesses were 110.6±7.4 µm (range: 97-125 µm) and 108.2±6.1 µm (range: 78-123 µm), respectively. The difference in the corneal flap thickness between the right and left eyes (2.4±6.5µm) was not significant (t=2.039, P=0.0506). The corneal flap thickness was positively correlated with the preoperative CCT through stepwise regression analysis (r=0.297, P=0.021). The corneal flap thickness was not related to age, spherical equivalent refraction, mean keratometry, or corneal diameter. The corneal flap thickness was estimated using the following equation: Tflap=67.77+0.076 CCT (F=5.63, P=0.021). CONCLUSION Both the Alcon Wavelight FS200 femtosecond laser and the MORIA SBK microkeratome produced 110-µm-thick corneal flaps. The central corneal flap thickness was positively correlated with the preoperative CCT in MORIA SBK microkeratome surgery.
منابع مشابه
The Impact of Flap Creation Methods for Sub-Bowman’s Keratomileusis (SBK) on the Central Thickness of Bowman’s Layer
PURPOSE To determine the impact of flap creation methods for sub-Bowman's keratomileusis (SBK) on central Bowman's layer thickness. METHODS SBK flaps were made by Moria microkeratome for 20 subjects and by femtosecond (FEMTO) laser for 21 subjects. Corneal sublayer thicknesses were measured by ultra-high resolution optical coherence tomography before SBK and at 1 day, 1 week, 2 weeks, and 1 m...
متن کاملThree-dimensional LASIK flap thickness variability: topographic central, paracentral and peripheral assessment, in flaps created by a mechanical microkeratome (M2) and two different femtosecond lasers (FS60 and FS200)
PURPOSE To evaluate programmed versus achieved laser-assisted in situ keratomileusis (LASIK) flap central thickness and investigate topographic flap thickness variability, as well as the effect of potential epithelial remodeling interference on flap thickness variability. PATIENTS AND METHODS Flap thickness was investigated in 110 eyes that had had bilateral myopic LASIK several years ago (av...
متن کاملCorneal flap thickness with the Moria M2 single-use head 90 microkeratome in 72 consecutive LASIK procedures
PURPOSE This study aimed to evaluate the accuracy and consistency of corneal flap thickness in laser-assisted in situ keratomileusis (LASIK) with the Moria M2 single-use head 90 microkeratome. METHODS The central corneal thickness of 72 (37 right, 35 left) eyes of 37 patients was measured by ultrasonic pachymetry preoperatively and intraoperatively after flap cut. The Moria M2 single-use head...
متن کاملPredictability of Corneal Flap Thickness in LASIK Using the WaveLight FS200 Femtosecond Laser
250 of 250 words) Purpose: To compare the intended versus resultant thickness of laser in situ keratomileusis (LASIK) flaps created with a new femtosecond laser (WaveLight FS200 Femtosecond Laser, WaveLight GmbH, Alcon Laboratories) and to report refractive outcomes at 3 months posttreatment. Setting: Wellington Eye Clinic, Dublin, Ireland Design: Retrospective consecutive case series Methods: ...
متن کاملCorneal flap thickness with the Moria M2 single-use head 90 microkeratome.
PURPOSE To analyse the accuracy of corneal flap thickness created in laser-assisted in situ keratomileusis (LASIK) using the Moria Model 2 (M2) single-use head 90 microkeratome. METHODS The corneal thickness of 300 (266 myopic and 34 hyperopic) eyes of 150 patients was measured by ultrasonic pachymetry preoperationally and intraoperationally after flap cut. The Moria M2 single-use head 90, in...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- International journal of ophthalmology
دوره 7 2 شماره
صفحات -
تاریخ انتشار 2014