We tested documented in vitro and ex vivo advantages of novel hyaluronan based heparin bonded extracorporeal circuits in a prospective randomized study. During the period from June until September 2005, 40 patients undergoing reoperation for coronary artery bypass grafting were allocated into two equal groups (n = 20): Group 1 was treated with hyaluronan-based heparin-bonded circuits and group 2 was treated with uncoated control circuits. Complete blood count, fibrinogen, albumin, C3a, interleukin-2 levels, and thromboelastographic data were documented after induction of anesthesia (T1) and heparin administration before cardiopulmonary bypass (CPB) (T2), 15 minutes after initiation of CPB (T3), before cessation of CPB (T4), 15 minutes after reversal with protamine (T5), and the first postoperative day at 8:00 a.m. (T6). Hollow fibers were collected for consecutive biomaterial analysis by optical and scanning electron microscopy (SEM). Desorbed protein deposition on fibers was compared by spectrophotometry. Leukocyte counts were lower in T4-T6 in group 1 (p < .05). Platelet counts demonstrated significant differences at T4 and T5 in coated group (p < .05). Albumin and fibrinogen levels were better preserved in Group 1 at T4, T5 and T4, T6, consecutively (p < .05). C3a and IL-2 levels were lower at T3-T5 and T4-T5 in intervention group (p < .05). Postoperative hemorrhage was 412 +/- 50 mL in group 1 and 684 +/- 50 ml in group 2 (p < .05). Respiratory support time was shorter in group 1 versus control (p < .05). Platelet adhesion was significantly lower in intervention group. Amount of desorbed protein was 1.44 +/- 0.01 mg/dL in group 1 and 1.94 +/- 0.01 mg/dL in control (p < .05). SEM and spectrophotometry demonstrated better surface preservation in the hyaluronan coated group. Novel hyaluronan-based heparin-bonded circuits reduce platelet adhesion-aggregation and protein adsorption and provide better perioperative clinical parameters through platelet, albumin, and fibrinogen-sparing effects.
منابع مشابه
THE jOURNAL OF EXTRA-CORPOREAL TECHNOLOGY Technique Perfusion Strategies for Low-Dose and Heparin-Free Bypass
An increasing number of clinical reports are being published regarding various uses of heparin-bonded extracorporeal bypass circuits with altered coagulation regimens. Although the reasons for lowered heparinization levels have been discussed, there has been a lack of information detailing perfusion strategies necessary to manage this emerging technology. The decreased use or elimination of hep...
متن کاملManagement of Heparin-Resistant Patients with Benefits? Maximizing Biocompatibility in Cardiopulmonary Bypass: Combining ATryn® Recombinant Antithrombin III and Carmeda® Heparin-Bonded Perfusion Circuits: A Case Series.
As many as 25% of our cardiopulmonary bypass (CPB) patients have a diminished heparin response and fail to reach a therapeutic activated clotting time (ACT). We treat a majority of these patients with antithrombin III (ATryn®, recombinant antithrombin III [rhAT], rEVO Biologics). Our current CPB circuit uses Medtronic Carmeda® coating. We observed less post-operative bleeding in a number of pat...
متن کاملHyaluronan based heparin free coated open and closed extracorporeal circuits for high risk coronary revascularization.
This prospective randomized study compares the inflammatory response and fibrinolytic activation of fully coated/uncoated and open/closed extracorporeal circuits (ECC) in high risk patients. Over a 2-month period, 48 patients with EuroSCOREs 6 or greater undergoing coronary revascularization were prospectively randomized to one of the four perfusion protocols: Group 1: Closed and totally hyalur...
متن کاملBiocompatible circuits: an adjunct to non-cardiac extracorporeal cardiopulmonary support.
The utilization of cardiopulmonary bypass systems, for circulatory and/or pulmonary support of patients undergoing non-cardiac procedures, has been previously reported. There is, however, a sub-group of patients for whom total systemic anticoagulation for cardiopulmonary support is extremely undesirable or contraindicated altogether, due to the presenting pathology or procedure to be performed...
متن کاملIn vitro evaluation of platelet reactivity toward annuloplasty devices treated with heparin coating: studies under flow conditions.
We have applied an in vitro perfusion model to explore the potential thrombogenicity of polyester annulolasty fabric used in valve repair and to investigate the possible thromboresistance characteristics conferred by a special heparin coating (Duraflotrade mark treatment). Samples of human blood from i) untreated or ii) heparin-coated extracorporeal circuits were recirculated through annular pe...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The journal of extra-corporeal technology
دوره 37 3 شماره
صفحات -
تاریخ انتشار 2005