Usefulness of non-lead aprons in radiation protection for physicians performing interventional procedures.

نویسندگان

  • Masayuki Zuguchi
  • Koichi Chida
  • Masaaki Taura
  • Yohei Inaba
  • Ayako Ebata
  • Shogo Yamada
چکیده

At present, interventional radiology (IVR) tends to involve long procedures (long radiation duration), and physicians are near to the source of scattered radiation. Hence, shielding is critical in protecting physicians from radiation. Protective aprons and additional lead-shielding devices, such as tableside lead drapes, are important means of protecting the physician from scattered radiation. The purpose of this study was to evaluate whether non-lead aprons are effective in protecting physicians from radiation during IVR procedures. In this study, the radiation protection effects of commercially available protective lead and non-lead aprons, when exposed to diagnostic X rays, are compared. The performance of these non-lead and lead aprons was similar for scattered X rays at tube voltages of 60-120 kV. Properly designed non-lead aprons are thus more suitable for physicians because they weigh approximately 20% less than the lead aprons, and are non-toxic.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Are Radiation Exposure Levels Used in Cardiology Dangerous?

Background: The number of interventional cardiology procedures performed has increased rapidly over the past years. While these procedures help physicians avoid using highly complicated invasive methods, it usually leads to high levels of exposure to ionizing radiation of both patients and cardiologist. The dose received by the cardiologist during interventional cardiology procedures is determi...

متن کامل

Evaluation of radiation exposure to physicians during hemodynamic interventional procedures* Avaliação da exposição dos médicos à radiação em procedimentos hemodinâmicos intervencionistas

OBJECTIVE: The present study evaluates the dose distribution received by physicians involved in hemodynamic procedures of coronary angiography and coronariography. The influence of some factors such as pulsed or continuous fluoroscopy mode and vein and/or artery access site was investigated. MATERIALS AND METHODS: Measurements have been performed with LiF:Mg,Ti thermoluminescent dosimeters plac...

متن کامل

Assessment of the Radiation Attenuation Properties of Several Lead Free Composites by Monte Carlo Simulation

Background:In diagnostic radiology lead apron, are usually used to protect patients and radiology staff against ionizing radiation. Lead apron is a desirable shield due to high absorption and effective attenuation of x-ray photons in the diagnostic radiology range.Objective: Although lead aprons have good radiation protection properties, in recent years, researchers have been looking for altern...

متن کامل

Evaluation of X-ray protective shielding used in dental offices in Kerman, Iran, in 2014

BACKGROUND AND AIM: Protective equipment, such as lead aprons and thyroid shields, is effective in reducing patient radiation. This study was conducted for evaluation the use of thyroid shields and lead aprons in dental offices, in Kerman, Iran, in June 2014.METHODS: In this descriptive-analytical study, 106 dental offices with active X-ray machines were evaluated in Kerman. The information was...

متن کامل

Comprehensive TLD dosimetry of physicians and patients during interventional angiography procedures to estimate the risk of radiation deterministic effect

Introduction: Interventional angiography procedures are increasingly used today. These techniques require a long time of standing near the patient and x-ray tube which lead to increase the radiation-dose of the staff and interventionists. This may also, in turn, lead to the occurrence of radiation deterministic effects. Since a large number of interventional radiology were perf...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiation protection dosimetry

دوره 131 4  شماره 

صفحات  -

تاریخ انتشار 2008