Validation of Contamw Predictions for Tracer Gas in a Townhouse

نویسندگان

  • Steven J. Emmerich
  • Steven J. Nabinger
  • Arpita Gupte
  • Cynthia Howard-Reed
چکیده

To provide additional validation data for the multizone airflow and contaminant model, CONTAMW, experiments were performed in an occupied 3-story townhouse in Reston, VA. A tracer gas, sulfur hexaflouride (SF6), was manually injected within one room of the house and the concentration of SF6 was measured in each zone. This same process was then recreated in CONTAMW and the resulting predictions were statistically compared to the measured values. A total of 10 experiments were conducted and simulated between May 2000 and June 2001. The tests involved injecting 1500 mL of 1 % SF6 in a single room of the house. In 4 of the 10 cases, the heating and air-conditioning system fan was operating. SF6 was injected in the Recreation Room (basement level), the Kitchen/Dining Room (main level) and the Master Bedroom (upstairs level). Ambient conditions ranged from a low outdoor temperature of 5 °C to a high of 29 °C. Wind conditions ranged from calm to moderate with a high average wind speed of 4 m/s. A statistical comparison of measurements and predictions was performed per ASTM D5157 (ASTM 1997) for all cases. Comparisons were made for overall zone average concentrations and individual zone transient concentrations. The results for zone average concentrations were very good with many cases meeting most or all of the D5157 criteria. Several cases showed a poor to fair correlation between average measurements and predictions due to discrepancies with a single zone the main floor bathroom but excluding that zone resulted in these cases meeting or nearly meeting the D5157 criteria. Comparisons of individual zone transient concentrations were mixed with many good to excellent cases but also numerous fair to poor. As expected, there were frequently large differences between measured and predicted peak concentrations. Also, the bathroom zone was a consistently difficult zone to predict accurately. Other zones had occasional poor comparisons between predictions and measurements but no consistent discrepancies. The predicted SF6 concentration averaged over all zones and cases was within 10 % of the average measured concentration. Excluding the bathroom zone, the overall average predicted concentration (115 μg/m) was essentially identical to the overall average measured concentration (116 μg/m).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ارزیابی عملکرد هودهای آزمایشگاهی براساس استاندارد  ASHRAE 110  در

Background and Aim: Laboratory fume-hoods are the first-level protection for the laboratory staff against hazardous chemical pollutants. Considering the large numbers of personnel, especially in petrochemical industry laboratories, this project was carried out in order to assess the performance of laboratory hoods based on tracer gas (SF6).Materials and Methods: In this project 22 hoods in the ...

متن کامل

Transparent Machine Learning Algorithm Offers Useful Prediction Method for Natural Gas Density

Machine-learning algorithms aid predictions for complex systems with multiple influencing variables. However, many neural-network related algorithms behave as black boxes in terms of revealing how the prediction of each data record is performed. This drawback limits their ability to provide detailed insights concerning the workings of the underlying system, or to relate predictions to specific ...

متن کامل

Modeling and Experimental Study of Carbon Dioxide Absorption in a Flat Sheet Membrane Contactor

comIn the present study, CO2 removal from natural gas stream has been studied using a flat sheet membrane contactor. A three dimensional mathematical model is developed to describe the process. The model considers the transport of a gas mixture containing carbon dioxide and methane through a flat sheet membrane contactor module. The model is based on the non-wetted mode of operation, in which t...

متن کامل

Effect of CO2 Concentration in Injecting Gas on Minimum Miscibility Pressure: Compositional Model and Experimental Study

For technical and economic success of miscible gas injection projects, an accurate laboratory measurement of Minimum Miscibility Pressure (MMP) at reservoir conditions is essential. On the other hand, compositional reservoir simulator is a useful tool in gas injection studies and prediction of MMP. The main goal of this paper is to describe a procedure to generate a three phase sequential t...

متن کامل

Validation of the 360-degree Appraisal through Assessment Center in the National Iranian Gas Company

The aim of this study has been validation of 360-degree Appraisal through assessment center in the National Iranian Gas Company. For this purpose, 76 of  key executives that participated in assessment center and 360-degree appraisal selected by available sampling. Data analyzed by SPSS software and Pearson correlation, linear regression, stepwise regression tests. The results showed 360-degree ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003