Potentiometric titration of sulphate, sulphite and dithionate mixtures, with use of a lead ion-selective electrode.

نویسندگان

  • P A Siskos
  • E P Diamandis
  • E Gillieron
  • J C Colbert
چکیده

Simple methods are described for the analysis of sulphate, sulphite and dithionate mixtures by potentiometric titration with lead perchlorate (and use of a lead ion-selective electrode). The error and precision are both about 2-5% for the sulphate concentration range 3 x 10(-3) -6 x 10(-4)M. The sulphur content in fuels derived from refuse was determined by potentiometric titration after bomb-combustion and the results compared favourably with those from the standard BaSO(4) gravimetric method.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Application of a dioxime-PVC electrode to potentiometric studies of Cr(III) ion

A PVC membrane Cr(III) ion selective electrode has been constructed using 2H-1,4-benzothioazine-2,3(4H)dione dioxime (BTD) as membrane carrier. The influence of membrane composition on the electroderesponse was studied. The electrode exhibits a Nernstian response over a Cr(III) concentration range of 1.0 x10 6 to 1.0>< 10-1 M (r = 0.99) with a slope of 19.5 ± 0.5 mV per decade of concentration,...

متن کامل

Chromium(III) ion selective electrode based on 2H-1,4-benzothioazine-2,3(4H)dione dioxime as a neutral carrier

A poly(vinyl chloride) membrane based on a new a-dioxime derivative as membrane carrier was prepared andinvestigated as a Cr(III) selective electrode. The electrode exhibits a good potentiometric response for Cr(III)over a wide concentration range 1.0 x 10-6 to 1.0 x 10-1 M with a slope 19.5+0.5 mV/decade and low detectionlimit of 8.9 x 10-7 M. It has a fast response time < 15 s. The best perfo...

متن کامل

Iodide selective membrane electrode based on copper (Π)-bis-Nphenilsalicyldenaminato complex

An iodide ion-selective PVC membrane sensor based on copper (Π)-bis-Nphenilsalicyldenaminatocomplex as a novel sensing material is successfully developed. Theelectrode showed a good selectivity for iodide ion with respect to common inorganic anions. Thesensor exhibited a good linear response with slope of _58.6 ± 0.4 mV per decade over theconcentration range of 5.0 × 10-6 to 1.0 × 10-1 mol L-1,...

متن کامل

High-Sensitive and Selective Liquid Membrane Electrode for Direct Determination of Trace Amounts of Chromium

N-(2H-[1,2,4]thiadiazolo[2,3-a]pyridine-2-ylidene)benzamide was used as a selective sensing material in the PVC membrane to construction of a new chromium ion selective electrode. This liquid membrane electrode worked well with a Nernstian response of 19.7 ±0.4 mV decade-1 of Cr(III) in a wide dynamic concentration range of 8.0× 10-6-1.0×10-1 M. The electrode had relatively short response time ...

متن کامل

Polymeric Membrane Sensor for Potentiometric Determination of Tin(II) Ions

Tin(II)-ion-selective electrode consisting of dibenzo-18-crown-6 (DB18C6) as an ionophore inPVC matrix was developed. The influences of membrane composition, selectivity, response time,reversibility and temperature on the electrode performance were investigated. The electrodeshowed a near Nernstian response for Sn2+ ions over a concentration range from 1.0× 10-6 – 1.0× 10-2 M with a slope of 27...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Talanta

دوره 30 12  شماره 

صفحات  -

تاریخ انتشار 1983