Intermediate frequency band digitized high dynamic range radiometer system for plasma diagnostics and real-time Tokamak control.

نویسندگان

  • W A Bongers
  • V van Beveren
  • D J Thoen
  • P J W M Nuij
  • M R de Baar
  • A J H Donné
  • E Westerhof
  • A P H Goede
  • B Krijger
  • M A van den Berg
  • M Kantor
  • M F Graswinckel
  • B A Hennen
  • F C Schüller
چکیده

An intermediate frequency (IF) band digitizing radiometer system in the 100-200 GHz frequency range has been developed for Tokamak diagnostics and control, and other fields of research which require a high flexibility in frequency resolution combined with a large bandwidth and the retrieval of the full wave information of the mm-wave signals under investigation. The system is based on directly digitizing the IF band after down conversion. The enabling technology consists of a fast multi-giga sample analog to digital converter that has recently become available. Field programmable gate arrays (FPGA) are implemented to accomplish versatile real-time data analysis. A prototype system has been developed and tested and its performance has been compared with conventional electron cyclotron emission (ECE) spectrometer systems. On the TEXTOR Tokamak a proof of principle shows that ECE, together with high power injected and scattered radiation, becomes amenable to measurement by this device. In particular, its capability to measure the phase of coherent signals in the spectrum offers important advantages in diagnostics and control. One case developed in detail employs the FPGA in real-time fast Fourier transform (FFT) and additional signal processing. The major benefit of such a FFT-based system is the real-time trade-off that can be made between frequency and time resolution. For ECE diagnostics this corresponds to a flexible spatial resolution in the plasma, with potential application in smart sensing of plasma instabilities such as the neoclassical tearing mode (NTM) and sawtooth instabilities. The flexible resolution would allow for the measurement of the full mode content of plasma instabilities contained within the system bandwidth.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intermediate frequency band digitized high dynamic range radiometer system for plasma diagnostics and real - time

• A submitted manuscript is the author's version of the article upon submission and before peer-review. There can be important differences between the submitted version and the official published version of record. People interested in the research are advised to contact the author for the final version of the publication, or visit the DOI to the publisher's website. • The final author version ...

متن کامل

Development and testing of a fast Fourier transform high dynamic-range spectral diagnostics for millimeter wave characterization.

A fast Fourier transform (FFT) based wide range millimeter wave diagnostics for spectral characterization of scattered millimeter waves in plasmas has been successfully brought into operation. The scattered millimeter waves are heterodyne downconverted and directly digitized using a fast analog-digital converter and a compact peripheral component interconnect computer. Frequency spectra are obt...

متن کامل

New Development of Epics-based Data Acquisition System for Millimeter-wave Interferometer in Kstar Tokamak

After successful achievement of the first plasma in 2008, Korea Superconducting Tokamak Advanced Research (KSTAR) has performed the 4 campaign in 2011. During the campaigns, many diagnostic devices have been installed for measuring the various plasma properties in the KSTAR tokamak. From the first campaign, a data acquisition (DAQ) system of Millimeter-wave interferometer (MMWI) has been operat...

متن کامل

Wide-Frequency Range, Dynamic Matching Network and Power System for the “Shoelace” RF Antenna on the Alcator C-Mod Tokamak

A wide-frequency range (50-300 kHz) power system has been implemented for use with a new RF antenna – the “Shoelace” antenna – built to drive coherent plasma fluctuations in the edge of the Alcator C-Mod tokamak. A custom, dynamically-tunable matching network allows two commercial 1 kW, 50-Ω RF amplifiers to drive the low-impedance, inductive load presented by the antenna. This is accomplished ...

متن کامل

Design and Testing of ECE Radiometer for Sinp-Tokamak

A multi channel ECE Radiometer, in the frequency range of 75 110 GHz, has been designed, constructed and tested for the SINP-Tokamak to diagnose second harmonic X-mode electron cyclotron emission (ECE). This frequency range covers approximately 80% of the plasma cross section in case of a magnetic eld of B = 1.5 T. For the maximum eld of the SINP-Tokamak B = 2.0 T, about 50% is covered. The ECE...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Review of scientific instruments

دوره 82 6  شماره 

صفحات  -

تاریخ انتشار 2011