Ureteral access sheaths: a comprehensive comparison of physical and mechanical properties.
نویسندگان
چکیده
INTRODUCTION Ureteral access sheaths (UAS) facilitate flexible ureteroscopy in the treatment of urolithiasis. The physical properties of UAS vary by manufacturer and model. We compared three new UAS: Glideway (GW, Terumo, 11/13Fr, 12/14Fr), Pathway (PW, Terumo 12/14F) and Navigator HD (NHD, Boston Scientific, 11/13Fr, 12/14Fr) in the domains of safety characteristics, positioning characteristics, lubricity and radioopacity. MATERIALS AND METHODS In vitro testing of the three UAS included safety testing-tip perforation force, sheath edge deformation and dilator extraction forces. Positioning characteristics tested included tip bending, stiffness (resistance to coaxial buckling forces), kinking (resistance to perpendicular forces), and insertion forces. Lubricity was assessed by measured frictional forces of the outer sheath. Finally, radio-opacity was tested utilizing fluoroscopic imaging of the three 12F sheaths and inner dilators. RESULTS The PW (0.245 lb) and GW (0.286 lb) required less force for tip perforation compared to the NHD (0.628 lb). The NHD sheath edge deformation was mild compared to more severe deformation for the PW and GW. The PW (1.008 lb) required greater force than the GW (0.136 lb) and NHD (0.043 lb) for inner dilator removal. The GW (3.69 lbs) and NHD (4.17 lb) had similar inner dilator tip stiffness when bent, while the PW had the weakest inner dilator tip, 1.91 lbs. The PW (0.271 lb) was most susceptible to buckling and kinking (1.626 lb). The most lubricious UAS was the NHD (0.055 lbs for 12F). The NHD (0.277 lbs) required the least insertional force through a biological model and possessed the greatest radio-opacity. CONCLUSIONS Comparison of different commercially available UAS in various sizes reveals that there are mechanical differences in sheaths that may play a role clinically. The Terumo sheaths' (GW and PW) were outperformed by the Boston Scientific NHD in simulating safety, ease of use and radio-opacity.
منابع مشابه
Systematic evaluation of ureteral access sheaths.
OBJECTIVES To compare the physical characteristics of ureteral access sheaths that affect their ability to resist buckling and kinking in the ureter. METHODS Eight commercially available ureteral sheaths were tested. The buckling pressure was measured by adding sequential loads to a point 20 cm from the tip of the sheath until the mass that resulted in buckling of the catheter was determined....
متن کاملComprehensive Comparison Between Mechanical Properties of Nanofiber Matrix and Single Nanofibers
متن کامل
Access, Stents, and Urinary Drainage
Ureteral access is necessary in many endourological procedures including ureteroscopy and ureteral stenting. Technologies such as ureteral access sheaths, balloon dilators, and coaxial dilators may be helpful in facilitating ureteral access in difficult cases. This chapter describes a stenting technique that relies on fluoroscopic guidance once the initial guidewire is placed and the cystoscope...
متن کاملPharmacological Relaxation of the Ureter When Using Ureteral Access Sheaths during Ureterorenoscopy: A Randomized Feasibility Study in a Porcine Model
Objective. High intraluminal pressure during ureterorenoscopy (URS) increases risk of infectious and haemorrhagic complications. Intrarenal pressure may be reduced by the use of ureteral access sheaths (UASs), which on the other hand may cause ureteral damage. We have previously shown that the β-agonist isoproterenol (ISO), when administered topically in the irrigation fluid, is able to inhibit...
متن کاملComparison of Properties of Ti/TiN/TiCN/TiAlN Film Deposited by Cathodic Arc Physical Vapor and Plasma-assisted Chemical Vapor Deposition on Custom 450 Steel Substrates
This study investigated the effects of deposition techniques on the microstructural and tribological properties of Ti/TiN/TiCN/TiAlN multilayer coatings onto a Custom 450 steel substrate. The coatings were produced using cathodic arc physical vapor deposition (CAPVD) and plasma-assisted chemical vapor deposition (PACVD). The microstructural of the coatings was evaluated using (SEM), and phase f...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- International braz j urol : official journal of the Brazilian Society of Urology
دوره 44 شماره
صفحات -
تاریخ انتشار 2018