The Comparative Study of Microsurgical Cerebral Aneurysm Clip Implants; Titanium Clip vs. Stainless Steel Clip
نویسندگان
چکیده
OBJECTIVE To perform a comparative study between two groups of populations, titanium (T) group versus stainless steel (S) group, who were clipped with titanium and stainless steel materials, respectively, the incidence of regrowth from the original aneurysms, the clip slippage, and post-clipping seizure attack were analyzed. The patients were followed more than 5 years after microsurgical cerebral aneurysms clipping. METHODS Data from 1986 through 2008 were extensively reviewed on a consecutive series of 3,770 patients who referred for ruptured/unruptured cerebral aneurysms. Forty-seven patients in the S group and 48 in the T group who met inclusion criteria, were selected for this study. RESULTS The incidence of regrowth were noted that two out of total 47 patients (4.3%) in the S group, and none in the T group. The clip slippage was not observed in both groups. And there was no statistical difference (p = 0.242) in terms of regrowth between two groups. Seven out of 47 cases (14.9%) developed post-clipping seizure in the S group. On the other hand, two (4.2%) of 48 patients presented the symptom in the T group. Also, there was no significant difference (p = 0.091) between two groups. CONCLUSIONS The metallic types of clip employed for the microsurgical cerebral aneurysm clipping does not have any significant clinical outcome differences in this study.
منابع مشابه
Aneurysm clips: evaluation of magnetic field interactions with an 8.0 T MR system.
This study was conducted to evaluate magnetic field interactions for aneurysm clips exposed to an 8.0 T magnetic resonance (MR) system. Twenty-six different aneurysm clips were tested for magnetic field translational attraction (deflection angle test) and torque (qualitative assessment method) using previously described techniques. Six of the specific aneurysm clips (i.e. type, model, blade len...
متن کاملComparison of Fluoroplastic Causse Loop Piston and Titanium Soft-Clip in Stapedotomy
Introduction:Different types of prosthesis are available for stapes replacement. Because there has been no published report on the efficacy of the titanium soft-clip vs the fluoroplastic Causse loop Teflon piston, we compared short-term hearing results of both types of prosthesis in patients who underwent stapedotomy due to otosclerosis.Materials and Methods:A total of 57 ears were included in ...
متن کاملClip blade scissoring with titanium bayonet clip in aneurysm surgery. Two case reports.
Scissoring of the cerebral aneurysm clip blades is a rare but potentially devastating complication of clipping surgery and results in aneurysm neck injury inducing rupture and/or cerebral infarction. Scissoring has been reported using titanium straight clips. Here we present two unusual cases of crossing of the blades of titanium bayonet clips by a scissors-like mechanism during surgery. The pr...
متن کاملMechanical Evaluation of Long Titanium Alloy Clip—Comparison of Cobalt Alloy Clip
Long titanium aneurysm clips have recently been released. In the present study, comparative study of long titanium and cobalt alloy clips was performed. Two kinds of Sugita long clips (straight clips of 25- and 35-mm blade length) made of titanium and cobalt alloys were tested by measuring the closing force, the anti-scissoring torque, and the maximum opening width. There were some differences ...
متن کاملIntraoperative angiography evaluation of the microsurgical clipping of unruptured cerebral aneurysms.
Intraoperative angiography evaluation of the clippings of cerebral aneurysms was investigated in a series of 38 consecutive patients with unruptured cerebral aneurysms to determine any favorable impact on the outcome. Unexpected findings including major arterial occlusion or residual aneurysm were identified. Specific variables such as the size and site of aneurysm were analyzed to determine th...
متن کامل