Impact of Prostate Volume on the Efficacy of High-Power Potassium-Titanyl-Phosphate Photoselective Vaporization of the Prostate: A Retrospective, Short-Term Follow-Up Study on Evaluating Feasibility and Safety

نویسندگان

  • Ja Hyeon Ku
  • Soo Woong Kim
  • Jae-Seung Paick
چکیده

PURPOSE We determined the impact of prostate volume on the efficacy of the high-power (80 W) potassium-titanyl-phosphate (KTP) photoselective laser vaporization of the prostate in men with lower urinary tract symptoms (LUTS). MATERIALS AND METHODS Patients were stratified into 3 groups according to prostate volume: '< 40 g' (n = 49) and '40-59 g' (n = 49) and '≥ 60 g' (n = 22). Median follow-up was 9 months (range 6 to 21). RESULTS No differences in age and follow-up duration were observed in the three groups. At baseline, no significant differences were noted in the three groups in terms of the International Prostate Symptom Score (IPSS) (21.4, 19.4 and 19.1; p = 0.412) as well as the maximum flow rate (Qmax) (10.2, 9.2, and 8.6 mL/s; p = 0.291) and post-void residual (PVR) (66.2, 80.4, and 71.5 mL; p = 0.856). The mean operative times were 30.9, 46.9, and 58.6 minutes (p< 0.001) and total median energy deliveries for each group were 62.3, 97.6, and 135.9 kJ, respectively (p< 0.001). No severe intraoperative complication was observed. At the last follow-up, these parameters improved significantly regardless of prostate volume, and the IPSS (11.1, 9.4, and 12.3; p = 0.286) as well as Qmax (15.9, 15.9, and 14.2 mL/s; p = 0.690) and PVR (33.7, 28.4, and 14.2 mL; p = 0.395) were not significantly different among the groups. CONCLUSION Although a larger prostate requires more time and energy delivery, photoselective laser vaporization of the prostate is safe and efficacious for patients with LUTS regardless of prostate volume.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Photoselective Vaporization of Prostate (KTP-PVP) Vs. Transurethral Resection of Prostate (TURP): A Prospective, Randomized Study

Objectives: To evaluate the efficacy and safety of photoselective vaporization of prostate (PVP) using a 100W potassium titanyl phosphate (KTP) laser in comparison to transurethral resection of prostate (TURP) in patients of benign prostatic enlargement (BPE). Materials and Methods: Between Jan 2014 and December 2015, 121 patients satisfying the eligibility criteria underwent surgery 62 PVP (Gr...

متن کامل

Photoselective Vaporization with KTP 180-W Green Laser for the Treatment of Lower Urinary Symptoms Secondary to Benign Prostatic Enlargement: Effectiveness and Safety at Midterm Follow-Up.

OBJECTIVES To determine safety, efficacy, and improvement in patient's quality of life (QoL) with 180-W green light laser prostate photovaporization in medium-term follow-up. METHODS Observational descriptive analysis. All the patients who were treated with photoselective vaporization with potassium titanyl phosphate crystal 180-W green laser between January 2012 and February 2014 were includ...

متن کامل

The Efficacy and Safety of Photoselective Vaporization of the Prostate with a Potassium-titanyl-phosphate Laser for Symptomatic Benign Prostatic Hyperplasia according to Prostate Size: 2-Year Surgical Outcomes

PURPOSE We investigated 2-year follow-up outcomes of patients who underwent potassium-titanyl-phosphate (KTP)-photoselective vaporization of the prostate (PVP) laser therapy for symptomatic benign prostatic hyperplasia (BPH). MATERIALS AND METHODS Of a total of 169 patients who underwent 80 W KTP-PVP by a single surgeon, we retrospectively analyzed the clinical data of 74 patients who complet...

متن کامل

Urethral injury during potassium-titanyl-phosphate laser prostatectomy complicated by transurethral resection syndrome.

The green light potassium-titanyl-phosphate laser photoselective vaporization of the prostate is the latest modality for treatment of benign prostatic obstruction. Because of effective superficial tissue coagulation, intravascular absorption of fluid is minimal; therefore, development of transurethral resection syndrome is unlikely. To our knowledge, this is the first report of a patient underg...

متن کامل

Treatment satisfaction after 1 year high-power potassium-titanyl-phosphate photoselective vaporization of the prostate.

To investigate the factors that influence treatment satisfaction after high-power potassium-titanyl-phosphate (KTP) laser vaporization of the prostate, we compared the characteristics between patients who were satisfied and those who were not satisfied. In all, 97 patients aged between 53-82 years (median age 67 years) underwent high-power KTP laser vaporization of the prostate for lower urinar...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 51  شماره 

صفحات  -

تاریخ انتشار 2010