Pseudo-rupture of Extensor Pollicis Longus following Kischner wire fixation of distal radius fractures.
نویسندگان
چکیده
We report two cases of extensor pollicis longus tendon tethering following K-wire insertion to treat unstable distal radius fractures, an unusual complication. In both cases, extensor pollicis longus function returned with conservative management. The structures considered "at risk" during K-wire insertion are described, and the common complications are discussed. Operative approaches to minimise soft tissue damage during K-wire insertion are reviewed. This case report is the first to demonstrate the potential for ultrasound scanning to aid in the diagnosis of extensor pollicis longus tethering.
منابع مشابه
The Prodrome of Extensor Pollicis Longus Tendonitis and Rupture: Rupture May Be Preventable.
Current literature suggests that tendonitis of the extensor pollicis longus (EPL) is a rare condition that has a high rate of progression to rupture. This study documents the prodrome of impending EPL rupture in patients with prior nondisplaced distal radial fracture. A retrospective study identified patients with EPL tendonitis or tendon rupture. Seven patients (6 females and 1 male) had susta...
متن کاملVolar plate fixation for the treatment of distal radius fractures: analysis of adverse events.
OBJECTIVES Determining the rate of specific adverse events after volar plating performed for distal radius fractures. DESIGN Retrospective. SETTING University level I trauma center. PATIENTS We searched the electronic database of all surgical procedures performed in our department using the following keywords: distal radius fracture, wrist fracture, and plate fixation. We identified 315 p...
متن کاملLate rupture of flexor pollicis longus tendon 10 years after volar buttress plate fixation of a distal radius fracture: a case report.
We report the case of a complete rupture of flexor pollicis longus tendon in a 30-year old-man 10 years after open reduction and internal fixation of a distal radius fracture with a volar buttress plate.
متن کاملRadius Styloid Process Fractures Treated with Break-Away Screws: Two Cases Report
One cm longitudinal incision was made on the radius styloid process. Dissection of soft tissue was performed with taking care of extensor pollicis brevis, abductor pollicis longus and superficial branch of radial nerve. Guide wire was inserted from tip of the radius styloid process. After surgeon recognized no displacement in fluoroscopy, break-away screw (Acutwist®, Nihon Medical Next, Osaka, ...
متن کاملPalmaris Longus Tendon Grafting for Extensor Pollicis Longus Tendon Rupture bScrew Tip after 20 years
INTRODUCTION Spontaneous ruptures of extension pollicis longus tendon predominantly occur after undisplaced or minimally displaced distal radial fracture near Lister tubercle. Systemic inflammatory diseases and systemic or local steroid, mechanical causes like bony ridges, presence of bone plate or external fixator pin may precipitate this. Repetitive uses in certain occupation like cooking, co...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Acta orthopaedica Belgica
دوره 70 5 شماره
صفحات -
تاریخ انتشار 2004