Ammonium dithionate- a new material for highly sensitive EPR dosimetry.
نویسندگان
چکیده
Polycrystalline ammonium dithionate has been examined for its radiation response in the low dose range (<5Gy) using EPR technique. The SO(3)(-) radical ion was detected as a single EPR line with a peak-to-peak derivative width of ca. 0.44mT in irradiated samples and its intensity was found to vary linearly with dose. At equal and moderate settings of microwave power and modulation amplitude ammonium dithionate was at least seven times more sensitive than l-alanine which is the most common EPR dosimeter standard. Pulse experiments were performed on the powder samples to obtain the longitudinal relaxation time. These and microwave saturation experiments served to indicate the optimal microwave power to be applied during measurements as an EPR dosimeter for best sensitivity of this material. It is thus claimed that ammonium dithionate has excellent potential to become an EPR dosimeter with a low limit of the measurable dose for cases where tissue equivalence is not required or can be corrected for.
منابع مشابه
Potassium dithionate EPR dosimetry for determination of absorbed dose and LET distributions in different radiation qualities
Potassium dithionate EPR dosimetry for determination of absorbed dose and LET distributions in different radiation qualities. Abstract With an increasing interest in using protons and light ions for radiation therapy there is a need for possibilities to simultaneously determine both absorbed dose (D) and linear energy transfer, LET, (LΔ). Potassium dithionate (K2S2O6) tablets were irradiated in...
متن کاملBarium dithionate as an EPR dosemeter.
Electron paramagnetic resonance (EPR) dosimetry is growing in popularity and this success has encouraged the search for other dosimetric materials. Previous studies of gamma-irradiated barium dithionate (BaS(2)O(6) x 2H(2)O) have shown promise for its use as a radiation dosemeter. This work studies in greater detail several essential attributes of the system. Special attention has been directed...
متن کاملHigh-resolution mapping of 1D and 2D dose distributions using X-band electron paramagnetic resonance imaging.
Electron paramagnetic resonance imaging (EPRI) was performed to visualise 2D dose distributions of homogenously irradiated potassium dithionate tablets and to demonstrate determination of 1D dose profiles along the height of the tablets. Mathematical correction was applied for each relative dose profile in order to take into account the inhomogeneous response of the resonator using X-band EPRI....
متن کاملEPR imaging of dose distributions aiming at applications in radiation therapy.
A one-dimensional electron paramagnetic resonance (EPR) imaging method for visualisation of dose distributions in photon fields has been developed. Pressed pellets of potassium dithionate were homogeneously irradiated in a (60)Co radiation field to 600 Gy. The EPR analysis was performed with an X-Band (9.6 GHz) Bruker E540 EPR and EPR imaging spectrometer equipped with an E540 GC2X two-axis X-b...
متن کاملRetrospective dosimetry using fingernail in nuclear industries: A review paper
Generally, doses greater than 2Gy can produce acute biological effects in humans. For this reason, to measure and record the cumulative dose, especially in radiation users, the need for a personal dosimeter has been strongly felt by the researchers. The purpose of this study is to introduce retrospective dosimetric techniques, in particular the use of nails as a natural tool for determining cum...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy
دوره 69 1 شماره
صفحات -
تاریخ انتشار 2008