3 Tesla and 7 Tesla MRI of multiple sclerosis cortical lesions.
نویسندگان
چکیده
Cortical lesions are prevalent in multiple sclerosis but are poorly detected using MRI. The double inversion recovery (DIR) sequence is increasingly used to explore the clinical relevance of cortical demyelination. Here we evaluate the agreement between imaging sequences at 3 Tesla (T) and 7T for the presence and appearance of individual multiple sclerosis cortical lesions. Eleven patients with demyelinating disease and eight healthy volunteers underwent MR imaging at 3T (fluid attenuated inversion recovery [FLAIR], DIR, and T(1)-weighted magnetization prepared rapid acquisition gradient echo [MP-RAGE] sequences) and 7T (T(1)-weighted MP-RAGE). There was good agreement between images for the presence of mixed cortical lesions (involving both gray and white matter). However, agreement between imaging sequences was less good for purely intracortical lesions. Even after retrospective analysis, 25% of cortical lesions could only be visualized on a single MRI sequence. Several DIR hyperintensities thought to represent cortical lesions were found to correspond to signal arising from extracortical blood vessels. High-resolution 7T imaging appeared useful for confidently classifying the location of lesions in relation to the cortical/subcortical boundary. We conclude that DIR, FLAIR, and MP-RAGE imaging sequences appear to provide complementary information during the detection of multiple sclerosis cortical lesions. High resolution 7T imaging may facilitate anatomical localization of lesions in relation to the cortical boundary.
منابع مشابه
Detecting multiple sclerosis cortical lesions post-mortem using 7 Tesla Magnetic Resonance Imaging
Introduction: Although originally considered a white matter (WM) disease, it is now clear that focal cortical grey matter (GM) pathology is an important component of multiple sclerosis (MS). Presently available magnetic resonance imaging (MRI) techniques fail in detecting the actual amount of cortical lesions (CLs). The reason for such a failure is twofold: (i) the small size of CLs relative to...
متن کاملIncreased cortical grey matter lesion detection in multiple sclerosis with 7 Tesla MRI : a postmortem verification study 2 . 3 7 T postmortem MRI and histopathology study
The relevance of cortical grey matter pathology in multiple sclerosis has become increasingly recognised over the past decade. Unfortunately, a large part of cortical lesions remain undetected on MRI using standard field strength. In vivo studies have shown improved detection by using higher magnetic field strengths up to 7 T. So far, a systematic histopathological verification of ultrahigh-fie...
متن کاملIn Vivo High-Resolution 7 Tesla MRI Shows Early and Diffuse Cortical Alterations in CADASIL
BACKGROUND AND PURPOSE Recent data suggest that early symptoms may be related to cortex alterations in CADASIL (Cerebral Autosomal-Dominant Arteriopathy with Subcortical Infarcts and Leukoencephalopathy), a monogenic model of cerebral small vessel disease (SVD). The aim of this study was to investigate cortical alterations using both high-resolution T2* acquisitions obtained with 7 Tesla MRI an...
متن کاملThe Optimization of Magnetic Resonance Imaging Pulse Sequences in Order to Better Detection of Multiple Sclerosis Plaques
Background and objective: Magnetic resonance imaging (MRI) is the most sensitive technique to detect multiple sclerosis (MS) plaques in central nervous system. In some cases, the patients who were suspected to MS, Whereas MRI images are normal, but whether patients don’t have MS plaques or MRI images are not enough optimized enough in order to show MS plaques? The aim of the current study is ...
متن کامل7 Tesla Magnetic Resonance Imaging to Detect Cortical Pathology in Multiple Sclerosis
BACKGROUND Neocortical lesions (NLs) are an important pathological component of multiple sclerosis (MS), but their visualization by magnetic resonance imaging (MRI) remains challenging. OBJECTIVES We aimed at assessing the sensitivity of multi echo gradient echo (ME-GRE) T2*-weighted MRI at 7.0 Tesla in depicting NLs compared to myelin and iron staining. METHODS Samples from two MS patients...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of magnetic resonance imaging : JMRI
دوره 32 4 شماره
صفحات -
تاریخ انتشار 2010