Bitoric laser in situ keratomileusis for the correction of simple myopic and mixed astigmatism.

نویسندگان

  • A S Chayet
  • M Montes
  • L Gómez
  • X Rodríguez
  • N Robledo
  • S MacRae
چکیده

OBJECTIVE To evaluate the safety and efficacy of bitoric laser in situ keratomileusis (LASIK) for the correction of simple myopic and mixed astigmatism. DESIGN Retrospective, single-center, and noncomparative case series. PARTICIPANTS Eighty-six eyes of 56 patients were analyzed for this study. Six-month and 1-year follow-up data were available on 86 eyes and 72 eyes, respectively. Eyes were divided in two groups according to the type of astigmatism: myopic astigmatism with low sphere (< -2 diopters) and mixed astigmatism. The range of astigmatism was 1.25 to 7.5 diopters. INTERVENTION LASIK was performed using the Automated Corneal Shaper (ACS) microkeratome (Bausch & Lomb, Claremont, CA) to create a cornea flap using the 130- or 160-micron thickness plate. A bitoric mid-stromal ablation was performed using the Nidek EC-5000 excimer laser (Nidek Company, Gamagori, Japan). MAIN OUTCOME MEASURES Uncorrected visual acuity, manifest refraction, and best spectacle-corrected visual acuity were the parameters measured preoperatively and at months 1, 3, 6, and 12. RESULTS At the last visit, an uncorrected visual acuity of 20/20 or better was achieved in 77% and 68% of the myopic and mixed astigmatism groups, respectively. Ninety-two percent of all eyes had a mean spherical equivalent within +/- 0.50 diopter of emmetropia. A mean decrease in the vectorial magnitude of the astigmatism of 94% and 91% was achieved for those eyes with myopic and mixed astigmatism, respectively. There was no loss of best spectacle-corrected visual acuity. In two eyes, the axis of the positive cylinder was misaligned. CONCLUSION Bitoric LASIK is an effective procedure to correct myopic and mixed astigmatism. Eighty-five percent of the eyes achieved an uncorrected visual acuity of 20/25 or better and had a final cylinder of 0.5 diopter or less. It is a safe operation, because no eyes lost any lines of best spectacle-corrected visual acuity. Longer follow-up may be needed to assess these results.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Laser in situ keratomileusis for mixed astigmatism using a modified formula for bitoric ablation.

PURPOSE To evaluate the results of treatment of mixed astigmatism with laser in situ keratomileusis (LASIK) by means of a modified Chayet formula for bitoric ablation and personalized nomogram calculations. METHODS A retrospective study was conducted in 19 consecutive eyes of 13 patients who underwent LASIK treatment of mixed astigmatism with a mean sphere of +1.63-/+1.23 D and a mean cylinde...

متن کامل

Clinical outcomes of wavefront-guided laser in situ keratomileusis to treat moderate-to-high astigmatism

PURPOSE The purpose of this study was to evaluate the refractive and visual outcomes of wavefront-guided laser in situ keratomileusis (LASIK) in eyes with myopic astigmatism and cylindrical component ≥2.0 diopter (D). METHODS In this retrospective study, 611 eyes that underwent LASIK for simple or compound myopic astigmatism were analyzed. Preoperative refractive cylinder ranged from -2.00 D ...

متن کامل

Refractive lenticule extraction (ReLEx) through a small incision (SMILE) for correction of myopia and myopic astigmatism: current perspectives

Small-incision lenticule extraction (SMILE) is an alternative to laser-assisted in situ keratomileusis (LASIK) and photorefractive keratectomy (PRK) for the correction of myopia and myopic astigmatism. SMILE can be performed for the treatment of myopia ≤-12 D and astigmatism ≤5 D. The technology is currently only available in the VisuMax femtosecond laser platform. It offers several advantages ...

متن کامل

Laser in situ keratomileusis for astigmatism ≤ 0.75 Diopter combined with low myopia: a retrospective data analysis

BACKGROUND This study examined the refractive and visual outcome of wavefront-optimized laser in situ keratomileusis (LASIK) in eyes with low myopia and compound myopic astigmatism ≤ 0.75 diopter (D). METHODS 153 eyes from 153 consecutive myopic patients (74 male, 79 female; mean age at surgery 40.4 ± 10.4 years) who had a preoperative refractive cylinder ≤ 0.75 D and a manifest sphere betwee...

متن کامل

Laser in situ keratomileusis in patients with corneal guttata and family history of Fuchs' endothelial dystrophy.

PURPOSE To report 1-year results of laser in situ keratomileusis (LASIK) in 7 eyes with corneal endothelial guttata and a family history of Fuchs' endothelial dystrophy. SETTING John Moran Eye Center, University of Utah, Salt Lake City, Utah, USA. METHODS A retrospective chart review was performed of 4 patients (7 eyes) who had trace to 1+endothelial guttata and a family history of Fuchs dy...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Ophthalmology

دوره 108 2  شماره 

صفحات  -

تاریخ انتشار 2001