Effects of heart rate in modified look-locker inversion recovery (MOLLI) T1 mapping

نویسندگان

  • Yoshinori Suizuki
  • Kunihiko Teraoka
  • Yoshiaki Komori
  • Andreas Greiser
چکیده

Background MOLLI is a method of producing a T1 map at end diastole by using the electrocardiogram (ECG) under respiratory arrest to obtain consecutive inversion recovery images with an arbitrary number of MOLLI cycles. Since a variety of heart rates are presumed clinically, it is important to understand their effects on the T1 value and the error of measurement. We investigated the error of measurement in MOLLI T1 mapping caused by changes in the heart rate.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A segmented modified look-locker inversion recovery (MOLLI) sequence for high heart rate T1 mapping of mice

Background Quantitative T1 mapping provides myocardial tissue characterization for assessment of various cardiomyopathies. The Modified Look-locker (MOLLI) sequence is widely used for mapping the T1quantification, where multiple single-shot images are acquired along the T1 recovery curve after an inversion pulse. However, single-shot imaging becomes infeasible for mouse imaging at high heart ra...

متن کامل

Heart-rate independent myocardial T1-mapping using combined saturation and inversion preparation pulses

Background Myocardial T1 mapping remains a challenging task due to restrictions imposed by cardiac and respiratory motion. Modified Look-Locker Inversion Recovery (MOLLI) [1] is widely used for 2D cardiac T1-mapping. In MOLLI, the spin-lattice relaxation curve is sampled several times after a single magnetization preparation. The ECG triggered imaging induces a disturbance in the relaxation cur...

متن کامل

How Accurate Is MOLLI T1 Mapping In Vivo? Validation by Spin Echo Methods

T1 mapping is a promising quantitative tool for assessing diffuse cardiomyopathies. The purpose of this study is to quantify in vivo accuracy of the Modified Look-Locker Inversion Recovery (MOLLI) cardiac T1 mapping sequence against the spin echo gold standard, which has not been done previously. T1 accuracy of MOLLI was determined by comparing with the gold standard inversion recovery spin ech...

متن کامل

Selection of magnetization catalyzation and readout methods for modified Look-Locker inversion recovery: a T1 mapping primer.

BACKGROUND The purpose of this work was to evaluate different magnetization preparation and readout sequences for modified Look-Locker inversion recovery (MOLLI) toward improved T1 mapping in the heart. Elements investigated include: catalyzation sequences to prepare the magnetization before readout, alternate k-space trajectories, a spoiled gradient recalled echo readout, and a 5b(3b)3b MOLLI ...

متن کامل

Improved segmented modified Look-Locker inversion recovery T1 mapping sequence in mice

OBJECT To develop and evaluate a 2D modified Look-Locker (MOLLI) for high-resolution T1 mapping in mice using a 3T MRI scanner. MATERIALS AND METHODS To allow high-resolution T1 mapping in mice at high heart rates a multi-shot ECG-triggered 2D MOLLI sequence was developed. In the proposed T1 mapping sequence the optimal number of sampling points and pause cardiac cycles following an initial a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 15  شماره 

صفحات  -

تاریخ انتشار 2013