Meniscal tears: comparison of the conventional spin-echo and fast spin-echo techniques through image processing
نویسندگان
چکیده
BACKGROUND Conventional spin-echo (PD-CSE) and fast spin-echo (PD-FSE) techniques are frequently used to detect meniscal tears. However, the time delay for imaging with PD-CSE has resulted in its replacement with faster techniques, such as proton density fast spin-echo (PD-FSE), which has become a frequent tool at most diagnostic centres.Qualitative analysis shows that the PD-CSE technique is more sensitive, but other authors have not found significant differences between the aforementioned techniques. Therefore, we performed a quantitative analysis in this study that aims to measure differences in the quality of the images obtained with both techniques. METHODS We compared the PD-CSE and PD-FSE techniques by quantitatively analysing the obtained proton density images: the area shown, as well as the brightness and lesion contrast of the obtained image.A set of 100 images from 50 patients thought to contain meniscal tears of the knee were selected. These 100 images were obtained from all individuals using both the PD-CSE and PD-FSE techniques. The images were processed using software developed in Delphi. In addition to these quantifications, three physicians, who are specialists in radiology and capable of analysing magnetic resonance (MR) images of the musculoskeletal system, qualitatively analysed the diagnostic sensitivity of both techniques. RESULTS On average, samples obtained via the PD-CSE technique contained 22% more pixels in the lesion area. The contrast differed by 28%, and the brightness differed by 31%. The two techniques were correlated using Student's t-test, which showed a statistically significant difference. The specialists detected meniscal tears in 30 of the images obtained via the PD-CSE technique, while only 72% of these cases were detected via the PD-FSE technique. CONCLUSIONS The PD-CSE technique was shown to be superior to PD-FSE for all of the evaluated properties, making its selection preferable.
منابع مشابه
Comparison the Accuracy of Fetal Brain Extraction from T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (HASTE) MR Image with T2-True Fast Imaging with Steady State Free Precession (TRUFI) MR Image by Level Set Algorithm
Background Access to appropriate images of fetal brain can greatly assist to diagnose of probable abnormalities. The aim of this study was to compare the suitability of T2-True Fast Imaging with Steady State Free Precession (T2-TRUFI), and T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (T2- HASTE( magnetic resonance imaging (MRI) to extract the fetal brain using the level set algorithm...
متن کاملComparison of spin-echo MR pulse sequences for imaging of the brain.
PURPOSE To determine the value of the gradient- and spin-echo (GRASE) technique as compared with the fast spin-echo and conventional spin-echo techniques in MR imaging of the brain. METHODS Sixty-six patients with ischemic and neoplastic brain lesions were examined with T2-weighted spin-echo, fast spin-echo, and GRASE sequences. Three independent observers evaluated the contrast characteristi...
متن کاملAssessment of the Characteristics of MRI Coils in Terms of RF Non-Homogeneity Using Routine Spin Echo Sequences
Introduction: One of the major causes of image non-uniformity in MRI is due to the existence of non-homogeneity in RF receive and transmit. This can be the most effective source of error in quantitative studies in MRI imaging. Part of this non-homogeneity demonstrates the characteristics of RF coil and part of it is due to the interaction of RF field with the material being imaged...
متن کاملComparison of Three-Dimensional Double-Echo Steady-State Sequence with Routine Two-Dimensional Sequence in the Depiction of Knee Cartilage
Introduction: There are some routine two-dimensional sequences, including short tau inversion recovery (STIR), T2-weighted fast-spin echo (T2W-FSE), and proton-density fast spin-echo for diagnosing osteoarthritis and lesions of the knee cartilage. However, these sequences have some disadvantages, such as long scan time, inadequate spatial resolution, and suboptimal tis...
متن کاملComparison of MR pulse sequences in the detection of multiple sclerosis lesions.
PURPOSE To compare the sensitivity of conventional spin-echo, fast spin-echo, fast fluid-attenuated inversion recovery (FLAIR), and turbo gradient spin-echo MR sequences in the detection of multiple sclerosis lesions. METHODS Conventional spin-echo, fast spin-echo, fast FLAIR, and turbo gradient spin-echo sequences were performed on a 1.0-T MR imager in seven patients with clinically definite...
متن کامل