Early versus newer generation devices for transcatheter aortic valve implantation in routine clinical practice: a propensity score matched analysis
نویسندگان
چکیده
Aim Contemporary data comparing early versus newer generation transcatheter heart valve (THV) devices in routine clinical practice are lacking. We sought to compare the safety and efficacy of early versus newer generation THVs in unselected patients undergoing transcatheter aortic valve implantation (TAVI). Methods and results We performed a propensity score matched analysis of patients undergoing transfemoral TAVI at a single centre with early versus newer generation devices between 2007 and 2016. Patients were matched for balloon-expandable versus self-expandable valves and Society of Thoracic Surgeons score. The primary end point was the Valve Academic Research Consortium (VARC)-2 early safety composite end point at 30 days. Among the 391 matched pairs, no differences between early (21.2%) and newer generation (20.8%) THVs regarding the early safety composite end point (HR 0.98, 95% CI 0.72 to 1.33, P=0.88) were observed. The rates of valve embolisation (0.8% vs 4.2%, P=0.005), bleeding events (24.8% vs 32.0%, P=0.028) and moderate-to-severe paravalvular regurgitation (PVR) (3.1% vs 12.1%, P<0.001) were lower among patients receiving newer generation devices. Conversely, patients treated with early generation THVs less frequently experienced annulus rupture (0% vs 2.0%, P=0.008). Conclusion Newer compared with early generation THV devices were associated with a lower rate of valve embolisation, PVR and bleeding events.
منابع مشابه
Propensity score matched comparison of transcatheter aortic valve implantation versus conventional surgery in intermediate and low risk aortic stenosis patients: A hint of real-world.
BACKGROUND Recently, the use of transcatheter aortic valve implantation (TAVI) in inter-mediate-low risk patients has been evaluated in the PARTNER II randomized trial. However, in the last years, this therapy has been employed in this scenario with underreported results, as compared to surgical aortic valve replacement (SAVR). METHODS We enrolled 362 consecutive patients with severe symptoma...
متن کاملA 3-center comparison of 1-year mortality outcomes between transcatheter aortic valve implantation and surgical aortic valve replacement on the basis of propensity score matching among intermediate-risk surgical patients.
OBJECTIVES This study sought to compare all-cause mortality in patients at intermediate surgical risk undergoing transcatheter aortic valve implantation (TAVI) or surgical aortic valve replacement (SAVR). BACKGROUND Physicians are selecting "lower" surgical risk patients to undergo TAVI. No clinical data exist about the clinical outcomes of TAVI versus SAVR among intermediate-surgical-risk pa...
متن کاملRoutine Endovascular Treatment With a Stent Graft for Access-Site and Access-Related Vascular Injury in Transfemoral Transcatheter Aortic Valve Implantation.
BACKGROUND Access-site and access-related vascular injury (ASARVI) is still a major limiting factor in transcatheter aortic valve implantation and affects the outcome of patients. Management strategies for ASARVI include manual compression, stent grafts, and vascular surgery. We hypothesized that the standard use of a self-expanding stent graft for the management of ASARVI is feasible and safe....
متن کاملComparison of two valve systems for transapical aortic valve implantation: a propensity score-matched analysis.
OBJECTIVES Several alternative transapical (TA) aortic prostheses for aortic valve implantation (AVI) have recently become available. Data directly comparing the performance of these different TA-AVI valves, however, are sparse. Therefore, we sought to analyse the performance of the better-established balloon-expandable SAPIEN XT™ valve system, and compare it with the recently approved self-exp...
متن کاملMatched Comparison of Self-Expanding Transcatheter Heart Valves for the Treatment of Failed Aortic Surgical Bioprosthesis
Background—Transcatheter valve-in-valve implantation is an established therapy for high-risk patients with failed surgical aortic bioprosthesis. There are limited data comparing outcomes of valve-in-valve implantation using different transcatheter heart valves (THV). Methods and Results—Patients included in the Valve-in-Valve International Data registry (VIVID) and treated with selfexpanding TH...
متن کامل