Effect of tracer arrival time on the estimation of the myocardial perfusion in DCE-CMR

نویسندگان

  • Niloufar Zarinabad
  • Gilion Hautvast
  • Marcel Breeuwer
  • Eike Nagel
  • Amedeo Chiribiri
چکیده

Background An accurate segmental myocardial blood flow (MBF) quantification can be performed by means of signal deconvolution techniques. The accuracy of MBF estimates relies on the precise identification of the tracer arrival time in the myocardium (tOnset). Voxelwise MBF quantification is likely to be more subject to such error than segmental MBF analysis due to the lower signal-to-noise ratio of myocardial signal intensity curves. Automated tOnset detection methods would be therefore warranted. The aim of this study was to assess the importance to of tOnset identification on voxelwise MBF quantification and to describe an automated algorithm to detect the optimal tOnset which minimizes the error in MBF estimates.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluating the Effect of Injected Dose of 99mTc- MIBI on the Quantitative Parameters of Myocardial Perfusion Imaging

Background: 99mTc-MIBI cardiac perfusion scanning is recognized as a clinically useful method in evaluating coronary artery disease. By the implementation of new imaging techniques and systems, it seems possible to obtain high-quality images with a lower dose of radiopharmaceuticals. The purpose of this study was to evaluate the effect of injection dose of 99mTc-MIBI on quantitative parameters ...

متن کامل

Head-to-head comparison of myocardial perfusion SPECT and CMR for assessment of myocardial ischemia

Background Myocardial perfusion single photon emission computed tomography (MPS) and cardiac magnetic resonance (CMR) can be used for assessment of myocardial ischemia. The methods reveal different aspects of the pathophysiology associated with myocardial ischemia where MPS is based on uptake of a perfusion tracer in viable mitochondria whereas CMR is based on firstpass perfusion reflecting cor...

متن کامل

Persistent sub-diaphragmatic activity on the myocardial perfusion scan with 99mTc-Sestamibi

We present a female patient with atypical chest pain who was referred to our department for ischemia evaluation. 99mTc-MIBI myocardial perfusion scan with dipyridamole stress was performed. Sub-diaphragmatic activity in the hepatic tissue and then in the bowel loops caused severe overlap on the inferior wall even on consecutive delayed images. Dipyridamole stress was repeated for the...

متن کامل

Serial Myocardial Imaging after a Single Dose of Thallium-201

Although thallium-201 exercise scintigraphy has been established for the detection of myocardial ischemia and viability, little is known regarding the myocardial thallium-201 kinetics during angioplasty. Herein, we report a 77-year old man with angina pectoris, in whom serial myocardial imaging after a single dose of thallium-201 was helpful in identifying not only the culprit lesion and myocar...

متن کامل

DE-CMR and MPS for assessment of myocardial viability: to what extent do the two techniques agree?

Background DE-CMR (gadolinium contrast enhanced cardiac magnetic resonance imaging) and MPS (nuclear myocardial perfusion scanning) are two widely used techniques to assess myocardial ‘viability’. However each evaluates different aspects of the myocardium where MRI examines scar burden whilst resting MPS assesses respiring myocytes. DE-CMR offers better spatial and temporal resolution, but requ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2012