Numerical simulation of the fluid structure interactions in a compliant patient-specific arteriovenous fistula.

نویسندگان

  • Iolanda Decorato
  • Zaher Kharboutly
  • Tommaso Vassallo
  • Justin Penrose
  • Cécile Legallais
  • Anne-Virginie Salsac
چکیده

The objective of the study is to investigate numerically the fluid-structure interactions (FSI) in a patient-specific arteriovenous fistula (AVF) and analyze the degree of complexity that such a numerical simulation requires to provide clinically relevant information. The reference FSI simulation takes into account the non-Newtonian behavior of blood, as well as the variation in mechanical properties of the vascular walls along the AVF. We have explored whether less comprehensive versions of the simulation could still provide relevant results. The non-Newtonian blood model is necessary to predict the hemodynamics in the AVF because of the predominance of low shear rates in the vein. An uncoupled fluid simulation provides informative qualitative maps of the hemodynamic conditions in the AVF; quantitatively, the hemodynamic parameters are accurate within 20% maximum. Conversely, an uncoupled structural simulation with non-uniform wall properties along the vasculature provides the accurate distribution of internal wall stresses, but only at one instant of time within the cardiac cycle. The FSI simulation advantageously provides the time-evolution of both the hemodynamic and structural stresses. However, the higher computational cost renders a clinical use still difficult in routine.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparing the Effect of Cryotherapy and Acupressure on Pain Intensity of Arteriovenous Fistula Cannulation in Patients Hemodialysis

Introduction: Patients with kidney failure undergoing hemodialysis are frequently exposed to the hemodialysis needles are inserted into the arteriovenous fistulas; one of the important interventions in nursing care is use of nonpharmacological interventions for relief pain. Therefore, this study was conducted to compare the effect of cryotherapy and acupressure on the pain intensity of needle ...

متن کامل

Data Mining Performance in Identifying the Risk Factors of Early Arteriovenous Fistula Failure in Hemodialysis Patients

Background and Objectives: Arteriovenous fistula is a popular vascular access method for surgical treatment of hemodialysis patients. The method, however, is associated with a high rate of early failure varying in the range of 20-60%. Predicting early Arteriovenous fistula failure and its risk factors can help reduce its incidence, its hospitalization rate, and associated costs. In this study, ...

متن کامل

Spinal dural arteriovenous fistula : a case report

Background: Spinal dural AVF is the most common type of spinal vascular malformation. However, presenting symptoms differ according to site of spinal involvement. This study described a case of arteriovenous malformation with paraparesis and incontinence. Case Presentation: Diagnosis of patient was confirmed by clinical and imaging examination using magnetic resonance image and ruling out ot...

متن کامل

SPLENIC ARTERIOVENOUS FISTULA: A RARE LESION CAUSING BLEEDING ESOPHAGEAL VARICES

We report a case of a 40 year old man with portal hypertension caused by a splenic arteriovenous fistula that was diagnosed at laparotomy. He presented with bleeding esophageal varices and was initially treated by sclerotherapy. At laparotomy, portal pressure was 40 cmH20 but fell to 20 cm H20 after the fistula was treated with splenectomy. All symptoms disappeared shortly after operation ...

متن کامل

Study of Pulsatile Non-Newtonian Blood Flow Through Abdominal Aorta and Renal Arteries Incorporating Fluid- Structure Interaction

Background: The interaction between the blood and the vessel wall is of great clinical interest in studying cardiovascular diseases, the major causes of death in developed countries.Objective: To understand the effects of incorporating fluid-structure interaction into the simulation of blood flow through an anatomically realistic model of abdominal aorta and renal arteries reconstructed from CT...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • International journal for numerical methods in biomedical engineering

دوره 30 2  شماره 

صفحات  -

تاریخ انتشار 2014