Study of Parameters Affects the Dosimetry System

نویسندگان

  • OSMAN A. ELHANAFY
  • SEHAM E. ABDELKHALEK
  • Osman A. Elhanafy
چکیده

Purpose: This paper evaluates the mechanical parameters for three dimensions PTW automatic water phantom system (MP3-S) and its computer controlled measuring system (MEPHYSTO software version 7.3). Material and Methods: This study compares the scanning overall speed using the PTW water phantom and PTW MEPHYSTO software at different levels of overall speed 5, 10, 15, 20,30, 40, and 50mm/sec. These measurements are done for depth dose curve, beam profile and diagonal profile using different step intervals and different spatial resolutions (low, medium, and high). Results: The scanning overall speed for depth dose measurements using PTW water phantom is about 19% to 86% less than the scanning overall speed of MEPHYSTO software at different overall speed levels 5 to 50mm/sec at 1mm step size. There is no difference in scanning overall speed between beam profile and depth dose measurements using PTW water phantom, while the scanning overall speed at diagonal profile is about 21% to 55% less than PDD. Conclusion: This study compared between scanning overall speed using the PTW automated water phantom and PTW MEPHYSTO software. It showed that the scanning overall speed using the PTW water phantom is affected by changing the spatial resolution (low, medium and high) and by changing the scanning type (depth dose and diagonal profile). The facilities in the PTW MEPHYSTO software for increasing the scanning overall speed and saving the measurements time have not achieved its aim. Our recommendations first of all is to add a time factor beside the distance present in hand control of PTW water phantom to enable the user to know the true scanning overall speed, and second is doing quality assurance between the software and mechanical water phantom during the system calibration regularly. On the other hand to move from measurement to others using big step size the system is achieve it's aimed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Monte Carlo Evaluation of Gamma Knife Dose Profile in Real Brain Phantom

Introduction The Gamma Knife system is designed solely for non-invasive treatment of brain disorders, and it benefits from stereotactic surgical techniques. Dose calculations required in the system are performed by GammaPlan code; in this code, brain tissue is considered uniform. In the present study, we evaluated the effect of Gamma Knife system on the obtained dose through simulating a real ...

متن کامل

Development of an Advanced Optical Coherence Tomography System for Radiation Dosimetry

Introduction: According to the literature, optical coherence tomography (OCT) can be used measure radiation absorbed dose. This study was carried out to design a computed tomography system for the calculation of absorbed dose and optimization of dose delivery in radiotherapy using gel dosimeters. Material and Methods: An advanced charge-coupled device based OCT system was developed in laborator...

متن کامل

Evaluation of Effective Sources in Uncertainty Measurements of Personal Dosimetry by a Harshaw TLD System

Background: The accurate results of the individual doses in personal dosimety which are reported by the service providers in personal dosimetry are very important. There are national / international criteria for acceptable dosimetry system performance.Objective: In this research, the sources of uncertainties are identified, measured and calculated in a personal dosimetry system by TLD.Method: T...

متن کامل

Determining TG-43 brachytherapy dosimetry parameters and dose distribution for a 131Cs source model CS-1

Background: Monte Carlo determination of TG-43 brachytherapy dosimetry parameters and dose distribution calculation for 131Cs source model CS-1 are presented in this study. Materials and Methods: The dose distribution was calculated around the 131Cs Model CS-1 located in the center of 30 cm ×30 cm ×30 cm water, and soft tissue phantoms cube using MCNP code by Monte Carlo method. The percentage ...

متن کامل

Performance evaluation of gated volumetric modulated arc therapy

Background: Aim of this study is to evaluate the accuracy of the gated volumetric modulated arc therapy (VMAT/RapidArc) using 2D planar dosimetry, DynaLog files and COMPASS 3D dosimetry system. Materials and Methods: Pre-treatment quality assurance of 10 gated VMAT plans was verified using 2D array and COMPASS 3D dosimetry system. Advantage of COMPASS over 2D planar is that it provides the clin...

متن کامل

A Novel Biological Dosimetry Method for Monitoring Occupational Radiation Exposure in Diagnostic and Therapeutic Wards: From Radiation Dosimetry to Biological Effects

Background and Objective: Professional radiation workers are occupationally exposed to long-term low levels of ionizing radiation. Occupational health hazards from radiation exposure, in a large occupational segment of the population, are of special concern. Biological dosimetry can be performed in addition to physical dosimetry with the aim of individual dose assessment and biological effects....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014