Bilateral Achilles tendon ossification: diagnosis with ultrasonography and Single Photon Emission Computed Tomography/Computed Tomography. Case report.
نویسندگان
چکیده
Ossification of the Achilles tendon is a rare clinical condition characterized by the presence of one or more segments of variable sized ossified mass within the tendon. The cause of the condition is obscure. We present the case of a 41 year-old male patient with pain in the Achilles tendon due to bilateral ossification of the tendon near the calcaneus insertion. The case was evaluated by ultrasonography, single photon emission computed tomography, and transmission computed tomography. In this case, we regarded repetitive microtrauma as the cause of the ossification based on the bilateral occurrence.
منابع مشابه
Brain Single Photon Emission Computed Tomography Scan (SPECT) and Functional MRI in Systemic Lupus Erythematosus Patients with Cognitive Dysfunction: A Systematic Review
Objective(s): Systemic lupus erythematosus (SLE) is an autoimmune disease with a wide range of clinical manifestations. Cognitive dysfunction is one of the manifestations that could present prior to the emergence of any other neuropsychiatric involvements in SLE. Cognitive dysfunction is a subtle condition occurring with ahigh frequency. However, there is no data on the correlation of cognitive...
متن کاملPrediction of Changes in Left Ventricular Ejection Fraction after Off-Pump Coronary Artery Bypass Grafting Surgery by Myocardial Perfusion Single-Photon Emission Computed Tomography
Introduction: Left ventricular ejection fraction (LVEF) is considered to be the single most important prognostic factor in patients with previous myocardial infarction. LVEF is not improved in all patients after coronary artery bypass grafting (CABG). This study aimed to assess the possibility of prediction of LVEF changes after CABG using myocardial perfusion gated signle photon emission compu...
متن کاملMonte Carlo Study of the Effect of Backscatter Materail Thickness on 99mTc Source Response in Single Photon Emission Computed Tomography
Introduction SPECT projections are contaminated by scatter radiation, resulting in reduced image contrast and quantitative errors. Backscatter constitutes a major part of the scatter contamination in lower energy windows. The current study is an evaluation of the effect of backscatter material on FWHM and image quality investigated by Monte Carlo simulation. Materials and Methods SIMIND program...
متن کاملUtilization of an optimum low-pass filter during filtered back-projection in the reconstruction of single photon emission computed tomography images of small structures
Introduction:Low-pass filters eliminate noise, and accordingly improve the quality of filtered back-projection (FBP) in the reconstruction of single photon emission computed tomography (SPECT) images. This study aimed at selection of an optimum low-pass filter for FBP reconstruction of SPECT images of small structures. Material and Methods:Sp...
متن کاملSectional anatomy quiz
This mage based series comprises of a quiz pertaining to the identification of salient anatomical structures expected to be seen at a given level on the computed tomography (CT) followed by examples of multiple representative pathologies that can be seen at the same level in a routine clinical setting. It is expected that this will improve confidence of nuclear physicians in interpretation of t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medical ultrasonography
دوره 13 4 شماره
صفحات -
تاریخ انتشار 2011