Leg length discrepancy treatment with subtrochanteric shortening osteotomy and blade plate fixation.

نویسندگان

  • Paweł Koczewski
  • Aleksandra Zaklukiewicz
  • Iwona Rotter
چکیده

BACKGROUND Subtrochanteric femoral shortening osteotomy is a method of surgical treatment of lower limb discrepancy (LLD). It is less commonly used due to numerous limitations and the resulting decrease in height, which is an undesirable effect for most patients. The aim of this study was to analyze the results and complications of treatment of leg length discrepancy (LLD) by femoral shortening osteotomy fixed with a blade plate and screws. MATERIAL AND METHODS The study group comprised 18 patients treated by subtrochanteric shortening osteotomy fixed with a blade or straight plate and screws. The age of patients at the time of the operation ranged from 12 years and two months to 24 years and 3 months (mean 17 years and 8 months). Before the operation, the mean LLD amounted to 4.1cm (from 2,5 to 7,0). The size of the same-time resection of the femur at the level of the subtrochanteric osteotomy ranged from 2.5 cm to 5.0 cm (mean 3.7). The follow-up period ranged from 6 months to 15 years and 9 months (mean 3 years and 6 months). The analysis of the results was based on the following criteria. A good result was defined as obtaining an equal length of both legs or achieving the intended amount of shortening. A fair result was defined as a post-operative LLD from 0.5 cm to 1 cm. A poor result comprised patients with post-operative LLD greater than 1 cm or with complications that leave a lasting impact or complications requiring revision surgery. RESULTS A good result was obtained in 15 patients and a fair one in 3 patients. Complications appeared in 5 (28%) patients. The most common complication was delayed bone healing. Full weight -bearing of the operated limb was allowed between 12 and 32 weeks post-surgery (mean 19 weeks). The final LLD ranged from 0 cm to 3 cm (mean 0.6 cm). Equal limb length was obtained in 13 (72%) patients. CONCLUSIONS 1. Subtrochanteric femoral shortening osteotomy fixed with a plate and screws, taking into consideration the limitation of possible correction to 5-6 cm, is an effective method of treatment of lower limb discrepancy with a relatively low complication rate. 2. The most common complications of subtrochanteric shortening osteotomy are disorders of bone union. 3. The use of lag screws for stabilisation of the osteotomy with an angle plate may reduce the risk of complications.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Distal Femoral Osteotomy in Genovalgum: Internal Fixation with Blade Plate Versus Casting

Background:   To compare the results of two different ways of distal femoral osteotomy stabilization in patients suffering from genuvalgum: internal fixation with plate, and casting. Methods:   In a non-randomized prospective study, after distal femoral osteotomy with the zigzag method, patients were divided into two groups: long leg casting, and internal fixation with blade plate. For all pati...

متن کامل

Cementless Total Hip Arthroplasty Involving Trochanteric Osteotomy without Subtrochanteric Shortening for High Hip Dislocation

BACKGROUND Total hip arthroplasty with subtrochanteric shortening osteotomy is widely performed for high hip dislocation. However, suboptimal leg length discrepancy correction and nonunion of the osteotomy site remain concerns. Although total hip arthroplasty using trochanteric osteotomy without subtrochanteric osteotomy was introduced, cemented implants have been more commonly used than contem...

متن کامل

Cementless Total Hip Arthroplasty After an Iatrogenic Subtrochanteric Fracture due to Hardware Removal: A Case Report

Introduction: Total hip arthroplasty (THA) after proximal femoral fixation is a challenging procedure due to possible hardware-related complications. Case presentation: A 78-year-old female with hip osteoarthritis had a proximal femoral osteotomy fixed using a blade plate in the same femur 41 years ago. A two-step approach was planned. After a challenging...

متن کامل

Clinical Results of Complex Subtrochanteric Femoral Fractures with Long Cephalomedullary Hip Nail

PURPOSE Good results of the cephalomedullary nails have been reported in proximal femoral fractures recently. Based on length of nails and shape of screws fixed in a femoral head for proximal fragment fixation, the proper nail length was in dispute. The purpose of this study was to evaluate the clinical and radiological results of a long cephalomedullary hip nail for the treatment of comminuted...

متن کامل

بررسی تکنیک صفحه‌گذاری بیولوژیک در شکستگی‌های چند قطعه‌ای ساب‌تروکانتریک استخوان ران

Background: Comminuted subtrochanteric fractures have been a challenge for orthopedic surgeons in terms of appropriate reduction and stable fixation. Numerous methods have been used for the fixation of comminuted subtrochanteric fractures among which some are accompanied with technical difficulties and complications of their own. Regarding the results of previous studies, we decided to evaluate...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Ortopedia, traumatologia, rehabilitacja

دوره 16 4  شماره 

صفحات  -

تاریخ انتشار 2014