An in vivo comparison of barbed suture devices and conventional monofilament sutures for cosmetic skin closure: biomechanical wound strength and histology.
نویسندگان
چکیده
BACKGROUND Very little biomechanical or histological data exist in the peer-reviewed literature comparing absorbable monofilament sutures to commercially-available knotless, absorbable barbed suture devices for cosmetic closure of skin incisions. OBJECTIVES The authors compare two commercially-available knotless, barbed suture devices against a conventional monofilament suture in a porcine model for biomechanical wound strength and histological quality of healing. METHODS This prospective randomized trial included 18 animals randomly assigned among three groups, with six in each. A total of 192 incisions were closed in a porcine in vivo model and assessed for biomechanical strength and histology at postoperative Days 0, 3, 10, and 21. Each animal received all three test devices in a randomized, three-way matched design. Immediately following euthanasia, the skin incisions were excised for ex vivo biomechanical testing. RESULTS In the ex vivo analysis, Biosyn proved significantly stronger than the V-Loc 90 device at Day 0 and Quill Monoderm at Day 3. At no time point was there any difference in biomechanical strength between the two barbed suture devices. Differences in barb geometry, barb number, and helicity between the two barbed suture devices resulted in failure modes that were significantly different. All three test articles resulted in mild tissue reaction scores on histology. The V-Loc 90 device consistently had the lowest tissue reaction scores at all time periods, with the difference between the V-Loc 90 device and Quill being significant at postoperative Day 10. CONCLUSIONS Knotless, absorbable barbed suture devices are a safe and efficacious alternative for cosmetic skin closures and yield wound strength and tissue reaction scores that are comparable to those from closures performed with absorbable monofilament sutures and secured with knots.
منابع مشابه
Comparison of Three Different Methods of Skin Closure in Anterior Midline Incisions of the Knee
Background: Few clinical trials have studied the functional and cosmetic outcomes of different closure tech- niques of surgical incisions. Skin wound and incision closure methods may influence the healing process and cos- metic outcome. The present study aims at comparing three different suture techniques of skin closure. Methods: In a clinical trial, sixty patients with anterior cruciate liga...
متن کاملUse of barbed suture in robot-assisted mitral valvuloplasty.
Robot-assisted annuloplasty using a mitral band has a major issue: suturing is time consuming because knot tying is performed mechanically under endoscopic view. We suture the mitral band to the native valve by running sutures using the V-Loc barbed suture nonabsorbable wound closure device (Covidien, Mansfield, MA) with 3-0 monofilament. This technique allows rapid suturing of the band to the ...
متن کاملUse of a barbed suture in the closure of hip and knee arthroplasty wounds.
Wound closure in primary and revision total hip and knee arthroplasty is an essential and critical component of the procedure. A well-performed closure may take up to 20 to 30 minutes for primary and revision surgeries, respectively. Traditionally, a layered closure is performed using various forms of absorbable and nonabsorbable sutures placed in an interrupted fashion, requiring the surgeon t...
متن کاملUse of absorbable running barbed suture and progressive tension technique in abdominoplasty: a novel approach.
Certain general principles regarding abdominoplasty have remained constant throughout the last century, although incision patterns, fascial repair, and fatty contour techniques have varied. What has remained constant has been the use of a layered closure technique for final wound approximation, including in most cases the closure of Scarpa’s fascia, popularized by the work of Lockwood.1 Controv...
متن کاملA High-Strength, Absorbable, Antibacterial Knotless Tissue Control Device for Fascial Closure
PURPOSE OF REVIEW This review provides an overview of the STRATAFIX™ SYMMETRIC PDS™ Plus Knotless Tissue Control Device design and performance characteristics and highlights the device's relevance for use in gynecological procedures. Various device testing was conducted on tensile strength, fixation tab mass comparison to conventional suture knot tower, initiation stitch strength, and wound hol...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Aesthetic surgery journal
دوره 31 2 شماره
صفحات -
تاریخ انتشار 2011