Determination of estrogens in water samples using dispersive liquid liquid microextraction and high performance liquid chromatography.

نویسندگان

  • Mohammad Reza Hadjmohammadi
  • Seyedeh Saboora Ghoreishi
چکیده

A new method for the analysis of estrogens including estrone (E1), 17b- estradiol (E2) and diethylstilbestrol (DES) in aqueous samples was performed using dispersive liquid liquid microextraction (DLLME) and high- performance liquid chromatography (HPLC). In order to optimize DLLME some important parameters such as type and volume of extraction and disperser solvent, extraction time, ionic strength and pH of sample were studied and optimum condition was obtained. Under optimum condition (extraction solvent: 80 µL CCl4; dispersive solvent: 1.25 mL acetone; NaCl: 12% (w/w) and pH of sample = 10.0), the enrichment factors and extraction recoveries were 71.0-78.5 and 85.2-94.2 respectively. Linearity was observed in the range of 0.02-500.0 µg L-1 for DES and 0.03-500.0 µg L-1 for E1 and E2. Limits of detection were 0.008 µg L-1 for DES and 0.010 µg L-1 for E1 and E2. The relative standard deviations (RSDs) for determination of estrogens in water were in the range of 2.4-3.2% (n = 5).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Lighter than Water Dispersive Liquid-liquid Microextraction Coupled with High Performance Liquid Chromatography for Determination of Cholecalciferol and Calcifediol from Plasma

In this study, a dispersive liquid–liquid microextraction method using an extraction solvent lighter than water has been developed for the extraction and preconcentration of cholecalciferol and calcifediol from plasma samples followed by high performance liquid chromatography determination. Initially, acetonitrile and sodium chloride (NaCl) are added into the plasma as an extraction solvent and...

متن کامل

Determination of some B Vitamins in Sour Cherry Juice Using Dispersive Liquid-liquid Microextraction Followed by High-performance Liquid Chromatography

Dispersive liquid-liquid microextraction method (DLLME) combined with high-performance liquid chromatography-ultraviolet detection (HPLC-UV) was used to determine thiamine (B1), nicotinamide (B3) and pyridoxine (B6) in sour cherry juice. This method was rapid, simple and sensitive. Separation was accomplished using a C18 column. The optimum chromatographic conditions were found to be: mobile ph...

متن کامل

Determination of some B Vitamins in Sour Cherry Juice Using Dispersive Liquid-liquid Microextraction Followed by High-performance Liquid Chromatography

Dispersive liquid-liquid microextraction method (DLLME) combined with high-performance liquid chromatography-ultraviolet detection (HPLC-UV) was used to determine thiamine (B1), nicotinamide (B3) and pyridoxine (B6) in sour cherry juice. This method was rapid, simple and sensitive. Separation was accomplished using a C18 column. The optimum chromatographic conditions were found to be: mobile ph...

متن کامل

Determination of 2-phenylethanol in Rose Water Using Dispersive Liquid-Liquid Microextraction with Gas Chromatography Flame Ionization Detection

A simple and rapid microextraction procedure based on dispersive liquid-liquid microextraction (DLLME) coupled with gas chromatography-flame ionization detection (GC-FID) was developed for the extraction and analysis of 2-phenylethanol in rose water sample. In the proposed approach, carbon tetrachloride and ethanol were used as extraction and dispersive solvents, respectively. Some important pa...

متن کامل

Use of Temperature-controlled Ionic Liquid-assisted Dispersive Liquid-Liquid Microextraction Method for the Detection of Amoxicillin, Cloxacillin and Erythromycin Residues in Cow Milk using High Performance Liquid Chromatography

Background and Objectives: Different types of antibiotics are used indiscriminately in animal husbandry for the growth and treatment of livestock, which cause accumulation of antibiotic residues in livestock products such as milk. Long-term consumption of milk contaminated with antibiotic residues above the permissible limits is harmful to human health, causing antibiotic resistance problems. T...

متن کامل

Ionic Liquid-based Ultrasound-assisted In-situ Solvent Formation Microextraction and High-performance Liquid Chromatography for the Trace Determination of Polycyclic Aromatic Hydrocarbons in Environmental Water Samples

A green and efficient ionic liquid-based ultrasound-assisted in-situ solvent formationmicroextraction (IL-UA-ISFME) in combination with high-performance liquid chromatographyultravioletdetection (HPLC-UV) has been successfully developed for the trace determination offive selected polycyclic aromatic hydrocarbons (PAHs) in environmental water samples. In thismethod, a hydrophobic ionic liquid (1...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Acta chimica Slovenica

دوره 58 4  شماره 

صفحات  -

تاریخ انتشار 2011