Improved method for isotopic and quantitative analysis of dissolved inorganic carbon in natural water samples.

نویسندگان

  • Nelly Assayag
  • Karine Rivé
  • Magali Ader
  • Didier Jézéquel
  • Pierre Agrinier
چکیده

We present here an improved and reliable method for measuring the concentration of dissolved inorganic carbon (DIC) and its isotope composition (delta(13)C(DIC)) in natural water samples. Our apparatus, a gas chromatograph coupled to an isotope ratio mass spectrometer (GCIRMS), runs in a quasi-automated mode and is able to analyze about 50 water samples per day. The whole procedure (sample preparation, CO(2(g))-CO(2(aq)) equilibration time and GCIRMS analysis) requires 2 days. It consists of injecting an aliquot of water into a H(3)PO(4)-loaded and He-flushed 12 mL glass tube. The H(3)PO(4) reacts with the water and converts the DIC into aqueous and gaseous CO(2). After a CO(2(g))-CO(2(aq)) equilibration time of between 15 and 24 h, a portion of the headspace gas (mainly CO(2)+He) is introduced into the GCIRMS, to measure the carbon isotope ratio of the released CO(2(g)), from which the delta(13)C(DIC) is determined via a calibration procedure. For standard solutions with DIC concentrations ranging from 1 to 25 mmol . L(-1) and solution volume of 1 mL (high DIC concentration samples) or 5 mL (low DIC concentration samples), delta(13)C(DIC) values are determined with a precision (1sigma) better than 0.1 per thousand. Compared with previously published headspace equilibration methods, the major improvement presented here is the development of a calibration procedure which takes the carbon isotope fractionation associated with the CO(2(g))-CO(2(aq)) partition into account: the set of standard solutions and samples has to be prepared and analyzed with the same 'gas/liquid' and 'H(3)PO(4)/water' volume ratios. A set of natural water samples (lake, river and hydrothermal springs) was analyzed to demonstrate the utility of this new method.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Isotopic ((13)C) analysis of dissolved organic carbon in stream water using an elemental analyzer coupled to a stable isotope ratio mass spectrometer.

A technique for measurement of the stable isotope composition of dissolved organic carbon (DOC) in stream water, using an elemental analyzer (EA) coupled to an isotope ratio mass spectrometer (IRMS), is described. Stream water samples were concentrated by rotary evaporation, acidified to remove dissolved inorganic carbon (DIC), and dried in silver cups prior to analysis. Precision was evaluated...

متن کامل

Feasibility Study of Reducing the Total Dissolved Solids (TDS) from Contaminated Water in Radish Plant (Raphanus Sativus) Using Nano Activated Carbon and Zeolite

Applying Nanoporous Materials is an appropriate method for improving chemical quality of the water due to high surface area, internal porous structure (porosity), high absorption capability of harmful gases and liquids, and capability of reactivating the surface. Therefore, actions were carried out in order to investigate the effect of Activated carbon and Zeolite on reducing the total dissolve...

متن کامل

A robust and fast method of sampling and analysis of delta13C of dissolved inorganic carbon in ground waters.

The stable carbon isotopic composition of dissolved inorganic carbon (delta13C(DIC)) is traditionally determined using either direct precipitation or gas evolution methods in conjunction with offline gas preparation and measurement in a dual-inlet isotope ratio mass spectrometer. A gas evolution method based on continuous-flow technology is described here, which is easy to use and robust. Water...

متن کامل

Determination of uranium isotopes (234U, 238U) and natural uranium (U-nat) in water samples by alpha spectrometry

Background: Due to the potential public health effects of releases of uranium to the environment, isotopic determination and measurement of this radionuclide in environmental samples is very important. Achieving this goal, monitoring programs for this radionuclide seems necessary to be applied in many countries. Materials and Methods: The uranium was separated from the water samples using anion...

متن کامل

حذف کربن آلی محلول از نمونه‌های آبی توسط فرآیند اکسیداسیون فنتون

Background and Aim: Nowadays, regarding the increased human and geological activities, concentrations of toxic and carcinogenic disinfectant by-products– like Trihalomethanes -which have an organic base, in drinking water sources, has worryingly increased. Thus, the present study aimed at surveying the amount of dissolved organic carbon (doc) removed from aqueous solution by Fenton process. Mat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Rapid communications in mass spectrometry : RCM

دوره 20 15  شماره 

صفحات  -

تاریخ انتشار 2006