Precision and safety of the pulsed electron avalanche knife in vitreoretinal surgery.
نویسندگان
چکیده
BACKGROUND We have developed a new surgical instrument, called the pulsed electron avalanche knife (PEAK; Carl Zeiss Meditec, Jena, Germany), for precise, "cold," and tractionless dissection of tissue in liquid media. OBJECTIVE To evaluate the 3-dimensional damage zone induced by the PEAK compared with 2 other standard intraocular surgical instruments, diathermy and retinal scissors. METHODS Damage zone and minimum safe distance were measured in vitro on chick chorioallantoic membrane and in vivo on rabbit retina with the use of propidium iodide staining. RESULTS The PEAK produced a paracentral zone of cellular structure disruption surrounding a crater and a peripheral zone of structurally intact but abnormally permeable cells. The instrument induced a damage radius that varied from 55 to 300 micro m for the range of voltages and pulses typically used during surgery. For comparison, damage radius for microsurgical scissors was 50 micro m, and for diathermy, 400 to 850 micro m. The PEAK also damaged tissue up to 1.4 mm away by the creation of water flow that formed at the tip of convex probes during collapse of a cavitation bubble. Concave probes, which prevent formation of the water jet, eliminated this effect. CONCLUSIONS The PEAK operated well within accept-able safety limits and may greatly facilitate both posterior segment surgeries (eg, membrane dissection and sheathotomy) and anterior segment procedures (eg, capsulotomy, nonpenetrating trabeculectomy, and iridectomy).
منابع مشابه
Pulsed electron avalanche knife in vitreoretinal surgery.
PURPOSE To evaluate the advantages, disadvantages, safety, and surgical applicability of the pulsed electron avalanche knife (PEAK-fc), a new electrosurgical knife for "cold" and tractionless cutting, in vitreoretinal surgery. PEAK-fc is equipped with an integrated fiberoptic that makes bimanual procedures in intraocular surgery possible. METHODS A prospective consecutive trial of 18 eyes in ...
متن کاملPulsed electron avalanche knife (PEAK-fc) for dissection of retinal tissue.
OBJECTIVE To evaluate the effectiveness and precision of tractionless retinal tissue dissection by the advanced version of the pulsed electron avalanche knife for fine cutting (PEAK-fc; Carl Zeiss Meditec, Jena, Germany). METHODS Porcine retina (in vivo) and human retina (in vitro) were incised with the PEAK-fc using various pulse parameters. The globes were then processed for light microscop...
متن کاملAnterior capsulotomy with a pulsed-electron avalanche knife.
PURPOSE To evaluate a new pulsed-electron avalanche knife design for creating a continuous curvilinear capsulotomy (CCC) and compare the CCC with a mechanical capsulorhexis. SETTING Department of Ophthalmology, Stanford University, Stanford, California, USA. METHODS In this study, CCCs were created in freshly enucleated bovine eyes and in rabbit eyes in vivo. The cutting velocity was adjust...
متن کاملEffects of the pulsed electron avalanche knife on retinal tissue.
OBJECTIVES To evaluate the precision of retinal tissue dissection by the pulsed electron avalanche knife (PEAK) and to assess possible toxic effects from this device. METHODS To demonstrate precision of cutting, bovine retina (in vitro) and rabbit retina (in vivo) were incised with the PEAK. Samples were examined by scanning electron microscopy and histologic examination (light microscopy). T...
متن کاملPulsed electron avalanche knife for capsulotomy in congenital and mature cataract.
The pulsed electron avalanche knife (PEAK-fc, Carl Zeiss Meditec) is an electrosurgical cutting device that allows precise "cold" and traction-free tissue dissection. We describe its applicability and safety for anterior capsulotomy in a child with congenital cataract and an adult patient with mature cataract. The PEAK-fc was set at a voltage of 600 V and a pulse repetition rate of 80 Hz. Anter...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Archives of ophthalmology
دوره 121 6 شماره
صفحات -
تاریخ انتشار 2003