Comparison of long-term biocompability of PVDF and PP meshes.

نویسندگان

  • C D Klink
  • K Junge
  • M Binnebösel
  • H P Alizai
  • J Otto
  • U P Neumann
  • U Klinge
چکیده

BACKGROUND Abdominal hernia repair is the most frequently performed operation in surgery. Mesh repair in hernia surgery has become an integral component. Although meshes made of PVDF are already in clinical use, so far no data of long-term biocompability are available. METHODS In this study a PVDF mesh was compared to a polypropylene mesh with regard to its long-term biocompatibility. A total of 28 rats were randomized to two groups. Mesh material was implanted subcutaneously; animals were euthanized seven days and six months postoperatively. The quantity of inflammatory tissue response was characterized by measuring the diameter of the foreign body granuloma. Furthermore quality of cellular immune response (T-lymphocytes, macrophages, and neutrophils), and inflammation (COX-2) was analyzed by immunohistochemistry. Furthermore the collagen type I/III ratio was determined. RESULTS Macrophages, T-lymphocytes, neutrophiles, and COX-2 declined significantly up to six months postoperatively in comparison to day 7 for both PVDF and PP meshes, and in both groups the collagen ratio increased significantly in the course of time. PVDF meshes showed a foreign body granuloma size significantly reduced compared to PP (7 days: 20 ± 2 μm vs. 27 ± 2 μm; 6 months 15 ± 2 μm vs. 22 ± 3 μm; p < .001). However no significant differences were found analyzing cellular response six months postoperatively. CONCLUSIONS Our current data suggest that even in the long-term course after six months and despite a higher effective surface of the PVDF samples it showed a smaller foreign body granuloma than with PP whereas the cellular response was similar.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Correlating Physicochemical Properties of Commercial Membranes with CO2 Absorption Performance in Gas-Liquid Membrane Contactor

The gas-liquid membrane contactor (GLMC) is a promising alternative gas absorption/desorption configuration for effective carbon dioxide (CO2 ) capture. The physicochemical properties of membranes may synergistically affect GLMC performances, especially during the long-term operations. In this work, commercial polypropylene (PP) and polyvinylidene fluoride (PVDF) hollow fiber (HF) membranes wer...

متن کامل

New polymer for intra-abdominal meshes--PVDF copolymer.

PURPOSE Full tissue integration without adhesion formation is still a challenge for intra-abdominal mesh materials. Purpose of this study was to investigate the adhesive potential and fibrocollagenous ingrowth of a polymer blend of polyvinylidene fluoride and hexafluorpropylene (co-PVDF), an established suture material in vascular surgery, when placed as a mesh in the intra-abdominal position. ...

متن کامل

In vivo biocompatibility assessment of (PTFE–PVDF–PP) terpolymer-based membrane with potential application for glaucoma treatment

The aim of the work was to evaluate the in vivo biological behaviour of polymeric membrane materials for glaucoma implants. The base material was biostable synthetic terpolymer (PTFE-PVDF-PP) with proved biocompability (PN-EN ISO 10993). The samples manufactured in the form a membrane were subjected to chemical and physical treatment to create an open pore system within the polymer matrix. As a...

متن کامل

Inflammatory Reaction as Determinant of Foreign Body Reaction Is an Early and Susceptible Event after Mesh Implantation

PURPOSE To investigate and relate the ultrashort-term and long-term courses of determinants for foreign body reaction as biocompatibility predictors for meshes in an animal model. MATERIALS AND METHODS Three different meshes (TVT, UltraPro, and PVDF) were implanted in sheep. Native and plasma coated meshes were placed bilaterally: (a) interaperitoneally, (b) as fascia onlay, and (c) as muscle...

متن کامل

Long term outcome and quality of life after open incisional hernia repair - light versus heavy weight meshes

BACKGROUND Mesh repair of incisional hernia is superior to the conventional technique. From all available materials for open surgery polypropylene (PP) is the most widely used. Development resulted in meshes with larger pore size, decreased mesh surface and lower weight. The aim of this retrospective non randomized study was to compare the quality of life in the long term follow up (> 72 month)...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of investigative surgery : the official journal of the Academy of Surgical Research

دوره 24 6  شماره 

صفحات  -

تاریخ انتشار 2011