Electrical Harmonics Modeling of Office Equipments Using Matlab and Simulink

نویسندگان

  • Bora ACARKAN
  • Osman KILIÇ
چکیده

Harmonic current pollution is a one of the major power quality problem in electrical power systems. In office buildings one of the main harmonic sources is a large numbers of computer loads. Especially, personal computers apply harmonic distortions to their power supply systems. In this study, harmonics models of equipments, a MATLAB ® code and single-phase Simulink simulation models are developed for office equipments in order to analysis harmonic activity in neutral conductor.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Harmonics and Reactive Power Compensation Using Shunt Hybrid Filter

The supply current is distorted by the nonlinear load such UPS, DC drives, AC drives and arc furnace. This current harmonics derates the electrical equipments. Thus the current harmonics are reduced from the supply line using Shunt Hybrid filter. The Hysteresis controller controls the active filter thus the supply current tracks the reference fundamental current extracted by the synchronous ref...

متن کامل

Comparative Analysis of Filters to Mitigate Harmonics for Power Quality Enhancement

Due to the advancement in power electronic equipments and increase in the usage of non-linear loads in power distribution system, the undesirable harmonics are introduced that degrade the quality of power. Presence of harmonics are always detrimental to power system that results in irreversible failure of electrical components, sometimes apart from frequently known heating issues in it. There a...

متن کامل

A Matlab-Simulink Approach To Shunt Active Power Filters

Due to the wide spread of power electronics equipment in modern electrical systems, the increase of the harmonics disturbance in the ac mains currents has became a major concern due to the adverse effects on all equipment. This paper presents the analysis and simulation using Matlab Simulink of a three-phase four wire neutral clamped active power filter (APF) compensating the harmonics and reac...

متن کامل

Harmonics Estimation in Power Systems using a Fast Hybrid Algorithm

In this paper a novel hybrid algorithm for harmonics estimation in power systems is proposed. The estimation of the harmonic components is a nonlinear problem due to the nonlinearity of phase of sinusoids in distorted waveforms. Most researchers implemented nonlinear methods to extract the harmonic parameters. However, nonlinear methods for amplitude estimation increase time of convergence. Hen...

متن کامل

Power quality improvement with a shunt active power filters using MATLAB / Simulink

Abstract: Along with the increasing demand on improving power quality i.e generally defined as any change in power (voltage, current, or frequency) that interferes with the normal operation of electrical equipment, the most popular technique that has been used is Active Power Filter (APF); This is because Passive filters performance is limited to a few harmonics and they can introduce resonance...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006