An image‐guided technique for planning and verification of supine craniospinal irradiation
نویسندگان
چکیده
We present a technique for planning and verification of craniospinal treatment with the patient in the supine position. Treatment delivery and verification is streamlined through the use of modern imaging techniques. Treatments use two lateral brain fields abutted to a single or pair of posterior spine fields. Treatment delivery is simplified by aligning all isocenters in the anterior-posterior and lateral directions. Patient positioning is accomplished via on-board kV imaging. Verification of field shape and junctions is accomplished with BB placement and MV portal imaging. Daily treatment is simplified by using only longitundinal couch shifts, which are recorded in the patient chart and RV database. The technique is simple to implement in a clinic that is already using a similar beam arrangement with the patient prone. It requires no additional devices to be fabricated (for immobilization or QA), and it takes advantage of all the existing elements of a modern linac.
منابع مشابه
Craniospinal Irradiation in Medulloblastoma using High Energy Medical Linear Accelerator: an Innovative Approach to Planning Technique
Background: Craniospinal irradiation (CSI) of medulloblastoma poses technological challenges due to the involvement of large treatment volume. Commonly, the whole treatment length is covered with two different isocentric plans in which the junction is shifted after every five fractions to overcome the possibility of hot and cold spot.Objective: This study aims to evaluate dosimetrically and cli...
متن کاملMethod to plan, administer, and verify supine craniospinal irradiation
Craniospinal irradiation remains an important technique in the management of malignancies of the central nervous system. It is technically demanding, with potential for treatment field overlap or gaps to yield unacceptable dosimetric heterogeneity. A method to accurately simulate and verify the three-field junction is described. We use a comfortable supine position to minimize patient movement....
متن کاملEvaluation of Dose Calculation Accuracy of Isogray Treatment Planning System in Craniospinal Radiotherapy
Introduction: Craniospinal radiotherapy is a therapeutic technique for central nervous system (CNS) tumors, which requires meticulous attention to technique and dosimetry.Treatment planning system (TPS) is one of the main equipment in radiotherapy; therefore, the evaluation of its accuracy is essential for dose calculation. The present study evaluates the validity of Isogray TPS in craniospinal...
متن کاملA simple technique for craniospinal radiotherapy in the supine position.
PURPOSE Craniospinal irradiation poses technical difficulties that may be addressed with the use of the newer technologies that have become available over the past decade. The use of CT simulation allows improved target localisation and beam geometry definition while significantly reducing the treatment simulation time. We have developed a CT-based technique for whole CNS irradiation in the sup...
متن کاملA simple approach of three-isocenter IMRT planning for craniospinal irradiation
PURPOSE To develop a new IMRT technique to simplify the process and improve efficiency in radiotherapy treatment planning for craniospinal irradiation (CSI) treatment. METHODS Image data of 9 patients who received CSI treatment in 2012 were used, the prescription was 36Gy in 20 fractions. Two treatment plans were created for each patient, one was with the new technique called three-isocenter ...
متن کامل