A 17-month evaluation of a chlorine dioxide water treatment system to control Legionella species in a hospital water supply.
نویسندگان
چکیده
OBJECTIVE To assess the safety and efficacy of a chlorine dioxide water treatment system in controlling Legionella in a hospital water supply. DESIGN For 17 months following installation of the system, we performed regular water cultures throughout the building, assessed chlorine dioxide and chlorite levels, and monitored metal corrosion. RESULTS Sites that grew Legionella species decreased from 41% at baseline to 4% (P = .001). L. anisa was the only species recovered and it was found in samples of both hot and cold water. Levels of chlorine dioxide and chlorite were below Environmental Protection Agency (EPA) limits for these chemicals in potable water. Further, enhanced carbon filtration effectively removed the chemicals, even at chlorine dioxide levels of more than twice what was used to treat the water. After 9 months, corrosion of copper test strips exposed to the chlorine dioxide was not higher than that of control strips. During the evaluation period, there were no cases of nosocomial Legionella in the building with the system, whereas there was one case in another building. CONCLUSIONS Our results indicate that operation of a chlorine dioxide system effectively removed Legionella species from a hospital water supply. Furthermore, we found that the system was safe, as levels of chlorine dioxide and chlorite were below EPA limits. The system did not appear to cause increased corrosion of copper pipes. Our results indicate that chlorine dioxide may hold promise as a solution to the problem of Legionella contamination of hospital water supplies.
منابع مشابه
Investigation of Legionella Pneumophila bacteria in hospital water supply systems
Introduction: Legionella Pneumophila bacteria is known as one of the most important nosocomial infections and the most common cause of death in patients. This study was aimed to identify Legionella Pneumophila bacteria in hospital water supply systems. Material and Methods: This descriptive cross-sectional study was performed to identify Legionella pneumophila in hot and cold-water systems of i...
متن کاملComparison of disinfectants for biofilm, protozoa and Legionella control.
The aim of this study was to compare the efficiency of different disinfectants applicable to Legionella control in domestic water systems. A domestic water supply simulation unit that allowed simulation of real-world conditions was developed for this purpose. The system, consisting of seven identical rigs, was used to compare treatment efficiency under equivalent conditions of system design, ma...
متن کاملSafety and efficacy of chlorine dioxide for Legionella control in a hospital water system.
In a 30-month prospective study, we evaluated the efficacy of chlorine dioxide to control Legionella organisms in a water distribution system of a hospital with 364 patient beds and 74 skilled nursing beds. The number of hot water specimens positive for Legionella organisms decreased from 12 (60%) of 20 to 2 (10%) of 20. An extended time (18 months) was needed to achieve a significant reduction...
متن کاملEffectiveness of different methods to control legionella in the water supply: ten-year experience in an Italian university hospital.
We report our ten-year experience of hyperchlorination, thermal shock, chlorine dioxide, monochloramine, boilers and point-of-use filters for controlling legionella contamination in a hospital hot water distribution system. Shock disinfections were associated with a return to pre-treatment contamination levels within one or two months. We found that chlorine dioxide successfully maintained leve...
متن کاملبررسی میزان آلودگی منابع آبی بیمارستانهای شهرخرم آباد به باکتری لژیونلا پنوموفیلا در سال 1387
Background: Legionella is a negative aquatic bacterium and one of the most common nosocomial pathogen. Hospital environment in case of growth, aerosol transmission system and endangered individuals are the high potential location for growth and prevalence of this agent. The suitable temperature in water reservoirs and water distribution system empowered the growth of this bactria. The purpose...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Infection control and hospital epidemiology
دوره 24 8 شماره
صفحات -
تاریخ انتشار 2003