Investigation of the air kerma response of spherical ionization chambers for unfolded pulse height distributions of (60)Co and (137)Cs using the EGS4 Monte Carlo code.

نویسندگان

  • Kook Jin Chun
  • Gwang Ho Yoo
چکیده

Data required for the determination of the absolute air kerma rate for (60)Co and (137)Cs gamma-rays using spherical cavity chambers were calculated using the EGS4 Monte Carlo system. Mass energy-absorption coefficient ratio and the stopping power ratio were calculated for a 10 cm(3) primary standard graphite-walled ionization chamber from the unfolded energy pulse height distributions of (60)Co and (137)Cs sources. Wall correction factors and non-uniformity correction factors for two graphite and one air equivalent plastic walled ionization chambers were also calculated with EGS4 code. The wall correction factors were compared with those determined by an experimental extrapolation method. To check the accuracy of the calculations the results were compared with those obtained from other primary standard laboratories such as NIST and NRCC. For a 10 cm(3) graphite ionization chamber, the mass energy-absorption coefficient ratios were 0.99917 for (60)Co and 1.0004 for (137)Cs. The values differed by 0.02-0.05 % for (60)Co and 0.11 % for (137)Cs from those of two laboratories. The stopping power ratios were 0.99984 for (60)Co and 1.0087 for (137)Cs. Comparison with NIST values showed differences of 0.06 % for (60)Co and 0.04 % for (137)Cs. The wall correction factors were obtained and they were different by 0.6-1.1 % for (60)Co and (137)Cs compared to the experimental linear extrapolation method. These values were compared with Monte Carlo derived values from other laboratories. The non-uniformity correction factors were also calculated and they differed from unity, the traditional value used in most standard national metrology laboratories.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Unfolding X-ray spectrum in the diagnostic range using the Monte Carlo Code MCNP5

Introduction: Unfolding X-ray spectrum is a powerful tool for quality control of X-ray tubes. Generally, the acquisition of the X-ray spectrum in diagnostic radiology departments is complicated and difficult due to high photon flux. Measurement of x ray spectra using radiation detectors could not be performed accurately, because of the pulse pile up. Therefore, indirect methods...

متن کامل

Application of unfolding technique to HPGe detector using response functions calculated with the EGS4 Monte Carlo code.

The EGS4 Monte Carlo simulation technique was used to obtain the energy spectra of photons arriving at a detector from the pulse height distributions measured by the same detector. First, the measured pulse height distribution for incident photons from several radiation sources such as 60Co, 137Cs, 152Eu and 207Bi with a collimator are compared with those calculated using the EGS4 code to inves...

متن کامل

Changes in the U.S. Primary Standards for the Air Kerma From Gamma-Ray Beams

Monte Carlo photon-electron transport calculations have been done to derive new wall corrections for the six NBS-NIST standard graphite-wall, air-ionization cavity chambers that serve as the U.S. national primary standard for air kerma (and exposure) for gamma rays from (60)Co, (137)Cs, and (192)Ir sources. The data developed for and from these calculations have also been used to refine a numbe...

متن کامل

Investigation of Anisotropy Caused by Cylinder Applicator on Dose Distribution around Cs-137 Brachytherapy Source using MCNP4C Code

Introduction: Brachytherapy is a type of radiotherapy in which radioactive sources are used in proximity of tumors normally for treatment of malignancies in the head, prostate and cervix. Materials and Methods: The Cs-137 Selectron source is a low-dose-rate (LDR) brachytherapy source used in a remote afterloading system for treatment of different cancers. This system uses active and inactive sp...

متن کامل

Dosimetric investigation of high dose rate Ir-192 source with Monte Carlo method

Background: This study aims to calculate the air-kerma strength (SK), the dose rate constant (∧) and the dose rate profiles of a Gammamed 12i Ir-192 source by using the Monte Carlo technique and to compare the dose rate values with those calculated by the Abacus HDR treatment planning system (TPS). Materials and Methods: Air-kerma strength (in units of U; 1 U= μGy m2 h-1) and the dose ra...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of radiation research

دوره 48 5  شماره 

صفحات  -

تاریخ انتشار 2007