Flow-through microfluidic photoionization detectors for rapid and highly sensitive vapor detection.

نویسندگان

  • Hongbo Zhu
  • Robert Nidetz
  • Menglian Zhou
  • Jiwon Lee
  • Sanketh Buggaveeti
  • Katsuo Kurabayashi
  • Xudong Fan
چکیده

A photoionization detector (PID) is well known for its high sensitivity, large dynamic range, and non-destructive vapor detection capability. However, due to its tardy response, which results from the relatively large ionization chamber and dead volume, the application of the PID in gas chromatography (GC) has been limited. Here, we developed a rapid, flow-through, and highly sensitive microfluidic PID that was microfabricated directly on a conductive silicon wafer. The microfluidic PID has a significantly reduced ionization chamber volume of only 1.3 μL, nearly 10 times smaller than that of state-of-the-art PIDs and over 100 times smaller than that of commercial PIDs. Moreover, it has virtually zero dead volume due to its flow-through design. Consequently, the response time of the microfluidic PID can be considerably shortened, ultimately limited by its residence time (7.8 ms for 10 mL min(-1) and 78 ms for 1 mL min(-1)). Experimentally, the response of the microfluidic PID was measured to be the same as that of the standard flame ionization detector with peak full-widths-at-half-maximum of 0.25 s and 0.085 s for flow rates of 2.3 mL min(-1) and 10 mL min(-1), respectively. Our studies further show that the microfluidic PID was able to detect analytes down to the picogram level (at 3σ of noise) and had a linear dynamic range of six orders of magnitude. Finally, because of the very short distance between the electrodes, low voltage (<10 VDC, over 10 times lower than that in a regular PID) can be used for microfluidic PID operation. This work will open a door to broad applications of PIDs in gas analyzers, in particular, micro-GC and multi-dimensional GC.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rapid and highly sensitive detection by a real-time polymerase chain reaction using a chip coated with its reagents.

On-site detection by flow-through polymerase chain reaction (PCR) microfluidic systems for rapid and highly sensitive analysis, are significantly desired for bioanalytical and medical research. The conventional continuous-flow PCR chips realized rapid detection, but their sensitivity was very low (10(6) to 10(8) copies μL(-1)). We improved this drawback by coating the chip with a PCR reagents m...

متن کامل

Ultrasensitive vapor detection with surface-enhanced Raman scattering-active gold nanoparticle immobilized flow-through multihole capillaries.

We developed novel flow-through surface-enhanced Raman scattering (SERS) platforms using gold nanoparticle (Au-NP) immobilized multihole capillaries for rapid and sensitive vapor detection. The multihole capillaries consisting of thousands of micrometer-sized flow-through channels provide many unique characteristics for vapor detection. Most importantly, its three-dimensional SERS-active micro-...

متن کامل

A Portable and Power-Free Microfluidic Device for Rapid and Sensitive Lead (Pb2+) Detection

A portable and power-free microfluidic device was designed for rapid and sensitive detection of lead (Pb(2+)). 11-mercaptoundecanoic acid (MUA)-functionalized gold nanoparticles (MUA-AuNPs) aggregated in the presence of Pb(2+) for the chelation mechanism. When we performed this analysis on a polydimethylsiloxane (PDMS) microfluidic chip, the aggregations deposited onto the surface of chip and f...

متن کامل

PCR optimization: Improving of Human Cytomegalovirus (HCMV) PCR to Achieve a Highly Sensitive Detection Method

Polymerase chain reaction (PCR) is a rapid and simple technique with high sensitivity and specificity. Inthe recent years, PCR has been used for rapid detection of viral nucleic acids, such as Humancytomegalovirus (HCMV), whereas, PCR optimization is an important task to be done, especially beforeit’s diagnostic application. Annealing temperature, ion concentration (especially...

متن کامل

Numerical Study of Droplet Generation Process in a Microfluidic Flow Focusing

Microfluidic flow focusing devices have been utilized for droplet generation on account of its superior control over droplet size. Droplet based microfluidics addressed many scientific issues by providing a novel technological platform for applications such as biology, pharmaceutical industry, biomedical studies and drug delivery. This study numerically investigated the droplet generation proce...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Lab on a chip

دوره 15 14  شماره 

صفحات  -

تاریخ انتشار 2015