Physical and structural studies on the cryocooling of insulin crystals.

نویسندگان

  • Ardeschir Vahedi-Faridi
  • Jeffrey Lovelace
  • Henry D Bellamy
  • Edward H Snell
  • Gloria E O Borgstahl
چکیده

Reflection profiles were analyzed from microgravity-grown ( micro g) and earth-grown insulin crystals to measure mosaicity (eta) and to reveal mosaic domain structure and composition. The effects of cryocooling on single-domain and multi-domain crystals were compared. The effects of cryocooling on insulin structure were also re-examined. Microgravity crystals were of larger volume, were more homogeneous and were of higher quality than earth crystals. Several micro g crystals contained a single mosaic domain which encompassed all or nearly all of the crystal with an eta(avg) of 0.005 degrees. The earth crystals varied in quality and all contained multiple domains with an eta(avg) of 0.031 degrees. Cryocooling caused a 43-fold increase in eta for micro g crystals (eta(avg) = 0.217 degrees ) and an eightfold increase for earth crystals (eta(avg) = 0.246 degrees ). These results indicate that very well ordered crystals are not completely protected from the stresses associated with cryocooling, especially when structural perturbations occur. However, there were differences in the reflection profiles. For multi-mosaic domain crystals, each domain individually broadened and separated from the other domains upon cryocooling. Cryocooling did not cause an increase in the number of domains. A crystal composed of a single domain retained this domain structure and the reflection profiles simply broadened. Therefore, an improved signal-to-noise ratio for each reflection was measured from cryocooled single-domain crystals relative to cryocooled multi-domain crystals. The improved signal from micro g crystals, along with the increase in crystal size, facilitated the measurement of the weaker high-resolution reflections. The observed broadening of reflection profiles indicates increased variation in unit-cell parameters, which may be linked to cryocooling-associated structural changes and disorder.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High-pressure cryocooling for capillary sample cryoprotection and diffraction phasing at long wavelengths.

Crystal cryocooling is usually employed to reduce radiation damage during X-ray crystallography. Recently, a high-pressure cryocooling method has been developed which results in excellent diffraction-quality crystals without the use of penetrative cryoprotectants. Three new developments of the method are presented here: (i) Xe-He high-pressure cryocooling for Xe SAD phasing, (ii) native sulfur ...

متن کامل

Facilitating protein crystal cryoprotection in thick-walled plastic capillaries by high-pressure cryocooling.

Many steps in the X-ray crystallographic solution of protein structures have been automated. However, the harvesting and cryocooling of crystals still rely primarily on manual handling, frequently with consequent mechanical damage. An attractive alternative is to grow crystals directly inside robust plastic capillaries that may be cryocooled and mounted on the beamline goniometer. In this case,...

متن کامل

Solution of protein crystallographic structures by high-pressure cryocooling and noble-gas phasing.

Room-pressure flash-cryocooling of protein crystals is the standard way to reduce radiation damage during data collection. Typically, it is necessary to find cryoprotection conditions by trial and error, a process that is not always successful. Recently, a new method, high-pressure cryocooling, was developed that does not require penetrative cryoprotectants and typically yields very high qualit...

متن کامل

Reduction of lattice disorder in protein crystals by high-pressure cryocooling.

High-pressure cryocooling (HPC) has been developed as a technique for reducing the damage that frequently occurs when macromolecular crystals are cryocooled at ambient pressure. Crystals are typically pressurized at around 200 MPa and then cooled to liquid nitrogen temperature under pressure; this process reduces the need for penetrating cryoprotectants, as well as the damage due to cryocooling...

متن کامل

A high-pressure cryocooling method for protein crystals and biological samples with reduced background X-ray scatter.

High-pressure cryocooling has been developed as an alternative method for cryopreservation of macromolecular crystals and successfully applied for various technical and scientific studies. The method requires the preservation of crystal hydration as the crystal is pressurized with dry helium gas. Previously, crystal hydration was maintained either by coating crystals with a mineral oil or by en...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Acta crystallographica. Section D, Biological crystallography

دوره 59 Pt 12  شماره 

صفحات  -

تاریخ انتشار 2003