Determination of glucosamine in raw materials and dietary supplements containing glucosamine sulfate and/or glucosamine hydrochloride by high-performance liquid chromatography with FMOC-Su derivatization: collaborative study.

نویسندگان

  • Joseph ZiQi Zhou
  • Ted Waszkuc
  • Felicia Mohammed
چکیده

A collaborative study was conducted for determination of glucosamine in raw materials and dietary supplements containing glucosamine sulfate and/or glucosamine hydrochloride by high-performance liquid chromatography (HPLC) with N-(9-fluorenyl-methoxycarbonyloxy) succinimide (FMOC-Su) derivatization. Thirteen blind materials, one pair of which were duplicates, were tested by 12 collaborating laboratories. The test samples consisted of various commercial products, including tablets, capsules, drink mix, and liquids as well as raw materials, blanks, and those for spike recovery analyses. The tests with blank products and products spiked with glucosamine showed good specificity of the method. The average recoveries at spike levels of 100 and 150% of the declared amount were 99.0% with a relative standard deviation (RSD) of 2.1%, and 101% with an RSD of 2.3%, respectively. The test results between laboratories on each commercial product were reproducible with RSD values of no more than 4.0%, and the results were repeatable in the same laboratory with an average RSD of 0.7%. HorRat values ranged from 0.5 to 1.7 on both tests of spike recovery and reproducibility between laboratories on commercial products. The average determination coefficient of the calibration curves from the laboratories was 0.9995 with an RSD of 0.03%. All of the 12 collaborating laboratories succeeded in the study and none of their reported test results were outliers, partly indicating the robustness of the method. It is recommended that the method be accepted by AOAC INTERNATIONAL as Official First Action.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Precolumn derivatization LC–MS/MS method for the determination and pharmacokinetic study of glucosamine in human plasma and urine

A selective precolumn derivatization liquid chromatography-tandem mass spectrometric (LC-MS/MS) method for the determination of glucosamine in human plasma and urine has been developed and validated. Glucosamine was derivatized by o-phthalaldehyde/3-mercaptopropionic acid. Chromatographic separation was performed on a Phenomenex ODS column (150 mm×4.6 mm, 5 μm) using linear gradient elution by ...

متن کامل

Investigation on Counterfeit Glucosamine and Chondroitin Products in Iranian Pharmaceutical Markets

The purpose of this report is to present the results of analysis of actual glucosamine and/or chondroitin contents of several such products in the market place and to determine if they significantly deviate from their label claim. A total of fourteen products containing glucosamine sulfate and nine products containing chondroitin sulfate were evaluated. The amounts of glucosamine and chondroiti...

متن کامل

Investigation on Counterfeit Glucosamine and Chondroitin Products in Iranian Pharmaceutical Markets

The purpose of this report is to present the results of analysis of actual glucosamine and/or chondroitin contents of several such products in the market place and to determine if they significantly deviate from their label claim. A total of fourteen products containing glucosamine sulfate and nine products containing chondroitin sulfate were evaluated. The amounts of glucosamine and chondroiti...

متن کامل

Isotachophoretic Determination of Glucosamine and Chondroitin Sulphate in Dietary Supplements

Václavíková E., Kvasnička F. (2013): Isotachophoretic determination of glucosamine and chondroitin sulphate in dietary supplements. Czech J. Food Sci., 31: 55–65. Glucosamine and chondroitin sulfate, components of normal cartilage, are used as ingredients in dietary supplements intended to treat osteoarthritis and/or to support joint health. Of concern is the documented lack of quality in many ...

متن کامل

Liquid chromatographic analysis of glucosamine in commercial dietary supplements using indirect fluorescence detection.

A method of using indirect fluorescence detection is evaluated for the analysis of glucosamine in commercial dietary supplements following chromatographic separation. In this method, the eluting analyte, glucosamine, was detected by monitoring an increase in the fluorescence signal for L-tryptophan (L-Trp) or DL-5-methoxytryptophan (5-MTP) after glucosamine complexed with a copper(II) ion and r...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of AOAC International

دوره 88 4  شماره 

صفحات  -

تاریخ انتشار 2005