Biomechanical comparison of 4 different lateral plate constructs for distal fibula fractures.

نویسندگان

  • Tobin T Eckel
  • Richard R Glisson
  • Prashanth Anand
  • Selene G Parekh
چکیده

BACKGROUND Displaced lateral malleolar fractures are often treated with reduction and surgical stabilization. However, there has not been a comprehensive laboratory comparison to determine the most appropriate device for treating these patients. This study subjected a range of contemporary lateral fibular plates to a series of mechanical tests designed to reveal performance differences. METHODS Forty fresh frozen lower extremities were divided into 4 groups. A Weber B distal fibula fracture was simulated with an osteotomy and stabilized using 1 of 4 plate systems: a standard Synthes one-third tubular plate with interfragmentary lag screw, a Synthes LCP locking plate with lag screw, an Orthohelix MaxLock Extreme low-profile locking plate with lag screw, or a TriMed Sidewinder nonlocking plate. Controlled monotonic bending and cyclic torsional loading were applied and bending stiffness, torsional stiffness, and fracture site motion were quantified. Resistance to cyclic torsional loading was determined by quantifying the number of loads withstood before excessive rotation occurred. Correlation between bone mineral density and each of the mechanical measures was determined. RESULTS There was no difference in angulation or bending stiffness between plates. All plates except the LCP showed greater lateral deflection than in the other bending directions. Bending stiffness was lowest in lateral distal fragment deflection for all 4 plates. There was a positive correlation between bone mineral density and bending stiffness for all plate types. There was no difference in fracture site rotation between plate types in internal or external torsion, but internal rotation of the distal fragment consistently exceeded external rotation. Torsional stiffness in external rotation exceeded stiffness in internal rotation in nearly all specimens. LCP plates performed relatively poorly under cyclic torsion. CONCLUSIONS Significant differences in plate performance were not demonstrated. The effects of bone quality variability and differences in interfragmentary screw purchase resulted in data dispersion that confounded absolute ranking of plate performance. CLINICAL RELEVANCE Identification of an optimal lateral fibular plating system has the potential to improve the clinical outcome of malleolar fracture fixation, particularly when patient conditions are unfavorable.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biomechanical Benefits of the VariAx Distal Lateral Fibula Plate

Distal fibula fractures are the most common injury of weight bearing bones. Several studies have shown the benefit of locking plates especially in osteoporotic bone. The aim of this biomechanical study was to test the anatomically shaped VariAx Distal Lateral Fibula Plate in comparison to a commonly used 1/3 Tubular Plate. The implants were assembled to bone surrogates simulating a comminuted f...

متن کامل

Comparison of lateral locking plate and antiglide plate for fixation of distal fibular fractures in osteoporotic bone: a biomechanical study.

OBJECTIVES The purpose of this study was to compare the biomechanical properties of posterolateral antiglide plating and lateral locked plating for fixation of displaced short oblique fractures of the fibula in osteoporotic bone. METHODS Short oblique fractures of the distal fibula at the level of the syndesmosis were simulated with a fibular osteotomy and ligamentous sectioning in 18 paired ...

متن کامل

Challenges of Plate Fixation for Vancouver Type-C Fractures after a Well-Fixed Hip Arthroplasty Femoral Stem

The fixation of distal femoral fractures (Vancouver type-C fractures) following a well-fixed hip arthroplasty femoral stem has become a challenging issue for orthopedic surgeons due to the inter-prosthetic biomechanical effects such as negative, positive, and torsional strain. Surgeons have applied a range of constructs to overcome these difficulties. To minimize the risk of inter-prosthetic fr...

متن کامل

Evidence Based Development of a Novel Lateral Fibula Plate (VariAx Fibula) Using a Real CT Bone Data Based Optimization Process During Device Development

Development of novel implants in orthopaedic trauma surgery is based on limited datasets of cadaver trials or artificial bone models. A method has been developed whereby implants can be constructed in an evidence based method founded on a large anatomic database consisting of more than 2.000 datasets of bones extracted from CT scans. The aim of this study was the development and clinical applic...

متن کامل

A contoured locking plate: Biomechanical evaluation of an osteosynthesis for osteoporotic ankle fractures

Introduction Ankle fractures involving the distal fibula belong to the most common fractures. Operative treatment is indicated in unstable ankle fractures by open reduction and internal fixation with plate and screws. Especially in the elderly, the osteoporotic bone provides reduced stabilization of this fixation. Therefore, an implant providing improved mechanical stabilization could allow a m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Foot & ankle international

دوره 34 11  شماره 

صفحات  -

تاریخ انتشار 2013