A novel high-capacity ion trap-quadrupole tandem mass spectrometer.

نویسندگان

  • Andrew N Krutchinsky
  • Herbert Cohen
  • Brian T Chait
چکیده

We describe a prototype tandem mass spectrometer that is designed to increase the efficiency of linked-scan analyses by >100-fold over conventional linked-scan instruments. The key element of the mass spectrometer is a novel high ion capacity ion trap, combined in tandem configuration with a quadrupole collision cell and a quadrupole mass analyzer (i.e. a TrapqQ configuration). This ion trap can store >10(6) ions without significant degradation of its performance. The current mass resolution of the trap is 100-450 full width at half maximum for ions in the range 800-4000 m/z, yielding a 10-20 m/z selection window for ions ejected at any given time into the collision cell. The sensitivity of the mass spectrometer for detecting peptides is in the low femtomole range. We can envisage relatively straightforward modifications to the instrument that should improve both its resolution and sensitivity. We tested the tandem mass spectrometer for collecting precursor ion spectra of all the ions stored in the trap and demonstrated that we can selectively detect a phosphopeptide in a mixture of non-phosphorylated peptides. Based on this prototype instrument, we plan to construct a fully functional model of the mass spectrometer for detecting modification sites on proteins and profiling their abundances with high speed and sensitivity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Multistage Fragmentation of Ion Trap Mass Spectrometry System and Pseudo-MS3 of Triple Quadrupole Mass Spectrometry Characterize Certain (E)-3-(Dimethylamino)-1-arylprop-2-en-1-ones: A Comparative Study

A new approach was recently introduced to improve the structure elucidation power of tandem mass spectrometry simulating the MS(3) of ion trap mass spectrometry system overcoming the different drawbacks of the latter. The fact that collision induced dissociation in the triple quadrupole mass spectrometer system provides richer fragment ions compared to those achieved in the ion trap mass spectr...

متن کامل

Development of a capillary high-performance liquid chromatography tandem mass spectrometry system using SWIFT technology in an ion trap/reflectron time-of-flight mass spectrometer.

In this work a capillary high-performance liquid chromatography/tandem mass spectrometry system has been developed in a quadrupole ion trap/reflectron time-of-flight mass spectrometer. The broadband excitation for isolating a precursor ion is achieved by generating the stored waveform inverse Fourier transform waveform in real time. Following the isolation and cooling periods, an auxiliary AC v...

متن کامل

Screening of drugs and toxic compounds with liquid chromatography-linear ion trap tandem mass spectrometry.

BACKGROUND In clinical and forensic toxicology, general unknown screening is used to detect and identify exogenous compounds. In this study, we aimed to develop a comprehensive general unknown screening method based on liquid chromatography coupled with a hybrid triple-quadrupole linear ion trap mass spectrometer. METHODS After solid-phase extraction, separation was performed using gradient r...

متن کامل

Induced in-source fragmentation pattern of certain novel (1Z,2E)-N-(aryl)propanehydrazonoyl chlorides by electrospray mass spectrometry (ESI-MS/MS)

UNLABELLED BACKGROUND Collision induced dissociation (CID) in the triple quadrupole mass spectrometer system (QQQ) typically yields more abundant fragment ions than those produced with resonance excitation in the presence of helium gas in the ion trap mass spectrometer system (IT). Detailed product ion spectra can be obtained from one stage MS2 scan using the QQQ. In contrast, generating the...

متن کامل

Systematic comparison of a two-dimensional ion trap and a three-dimensional ion trap mass spectrometer in proteomics.

The utility and advantages of the recently introduced two-dimensional quadrupole ion trap mass spectrometer in proteomics over the traditional three-dimensional ion trap mass spectrometer have not been systematically characterized. Here we rigorously compared the performance of these two platforms by using over 100,000 tandem mass spectra acquired with identical complex peptide mixtures and acq...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • International journal of mass spectrometry

دوره 268  شماره 

صفحات  -

تاریخ انتشار 2007