Basic Study on the Development of a High-Resolution Breast CT
نویسندگان
چکیده
X-ray breast computed tomography (breast CT) was developed by some research groups to overcome the limitations of mammography. Breast CT is expected to be an effective diagnostic tool because it can generate threedimensional images of a breast. However, the spatial resolution of the existing system is not satisfactory for identifying microcalcifications within the breast. The purpose of this study was to develop a prototype of high-resolution breast CT system, and to evaluate the imaging properties of the developed system. Our experimental system consists of a microfocus X-ray tube and a flat panel detector with a C-arm frame, a bed, and their controllers. Images were reconstructed by using cone-beam X-ray projections and the Feldkamp-Davis-Kress algorithm. We used phantoms to experimentally evaluate three imaging properties and exposure dose. Consequently, the modulation transfer function value was 0.1 at the frequency of 6.0 LP/mm, which is higher than that of clinical CT and breast CT. Breast phantom microcalcifications were observed clearly. Furthermore, entrance surface dose in the experimental system was similar to that of mammography. These results indicate that our experimental system overcomes the limitations of both the mammogram and existing breast CT systems.
منابع مشابه
The effect of focal spot size on the spatial resolution of variable resolution X-ray CT scanner
Background: A variable resolution X-ray (VRX) CT scanner provides a great increase in the spatial resolution. In VRX CT scanners, the spatial resolution of the system and its field of view (FOV) can be changed according to the object size. One of the main factors that limit the spatial resolution of VRX CT scanner is the effect of the X-ray focal spot. Materials and Methods: A theoreti...
متن کاملValidation and evaluation of a GATE model for MAMMI PET scanner
Introduction:MAMMI is a dedicated PET based on high resolution detectors placed close to the breast. In this study, we presented a GATE model for the simulation of MAMMI scanner and model its performance of the MAMMI based on an adaptation of the NU 4-2008 NEMA standard. Methods:A detailed of geometry MAMMI system that uses scintillation crystals coupled...
متن کاملAplastic anemia evolving to myelodysplastic syndrome and later to a lymphoproliferative malignancy in a treated case of carcinoma breast: A case report emphasizing the importance of PET-CT in cutaneous T cell lymphoma
Although aplastic anemia (AA) and myelodysplastic syndrome (MDS) are separate entities with different management, distinction between the two can be difficult on morphological basis due to hypocellularity of bone marrow. MDS is one of the serious complications of AA. Karyotyping is definitive in the diagnosis of MDS. Better and robust investigations like 18F-Fluoro-deoxy-Glucose Posi...
متن کاملInvestigation of the Spatial Resolution and Field of View with Change of Magnification in VRX CT
Introduction: Variable resolution x-ray (VRX) CT is a new type of CT that can image objects at various spatial resolutions. In a VRX CT scanner, the spatial resolution increases at the cost of reduction in the field of view (FOV). An important factor that limits the spatial resolution of the VRX CT is the effect of focal spot size. Also, the optimum magnification is different at each incident a...
متن کاملApplication of Different methods for Reducing Radiation Dose to Breast during MDCT
The increased use of computed tomography (CT) and its high radiation dose have led to great concerns about its potential for radiation induced cancer risks. Breast is a radiosensitive tissue based on tissue weighting factors assigned by the International Commission on Radiological Protection (ICRP). Moreover, the dose is maximal on the surface of the patient. Therefore, strategies should be tak...
متن کامل