The Mvg Tray with Truncated Downcomers: Recent Progress

نویسندگان

  • M. Wehrli
  • M. Pilling
چکیده

Efficiency data for MVG trays with truncated downcomers are presented for the first time. Various operating conditions including vacuum and high pressure are considered. While 7 bar and 11 bar data are very promising it has been possible to show that a uniform liquid flow pattern does indeed affect the efficiency at atmospheric pressure positively. A special downcomer outlet device has been developed to achieve an optimum initial velocity and mass distribution on the tray.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Use of Directional Momentum Devices on Fractionation Trays

INTRODUCTION Since almost all industrial scale columns are round, the side downcomers present unique challenges for liquid distribution both to and from the downcomers. Liquid leaving these downcomers needs to spread outwardly, away from the flow path centerline, in order to evenly feed the diverging tray active area. Also, one of the characteristics of side downcomers is that they naturally te...

متن کامل

Metronidazole Vaginal Gel 1.3% in the Treatment of Bacterial Vaginosis: A Dose-Ranging Study

OBJECTIVE Metronidazole vaginal gel (MVG) 0.75% is a US Food and Drug Administration-approved, 5-day treatment for bacterial vaginosis (BV). This study tested the hypothesis that a shorter treatment course at a higher dose (MVG 1.3%) would yield similar efficacy to 5 days of MVG 0.75%. MATERIALS AND METHODS This phase 2, multicenter, randomized, controlled, investigator-blinded, dose-ranging ...

متن کامل

CFD Simulation of Concap Tray Hydrodynamics

This research includes both experimental and CFD investigation in the hydrodynamic behavior of a new type of column tray introduced as “Concap” tray. The proposed column tray is used in contactor columns especially in stripping columns. The hydrodynamics of this Concap tray is investigated in a 1.2m in diameter column. Using air-water system, the experiments were performed for different liquid ...

متن کامل

Tissue Doppler imaging differentiates physiological from pathological pressure-overload left ventricular hypertrophy in rats.

BACKGROUND The myocardial velocity gradient (MVG) is a recent index of regional myocardial function derived from endocardial and epicardial velocities obtained by tissue Doppler imaging (TDI). This index might be useful for discriminating between physiological and pathological left ventricular hypertrophy (LVH) and for documenting the early transition from compensated LVH to heart failure. We s...

متن کامل

Experimental study of hydrodynamic characteristics of improved sieve tray with push valves

This paper addresses an experimental investigation in the hydrodynamic behavior of a modified slotted sieve tray. Slotted sieve tray (Push valve sieve tray) is a sieve tray that the push valves have been utilized on the tray deck to eliminate liquid gradients and non-uniformity of liquid distribution on the tray. The air-water system was used in an industrial scale experimental rig with an inte...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002