[Automated perimetry in patients with primary congenital glaucoma].
نویسندگان
چکیده
PURPOSE To identify and characterize defects using the automated perimetry test in patients with primary congenital glaucoma. METHODS Automated visual fields and charts of 81 eyes (48 patients) with congenital glaucoma were retrospectively analyzed, 15 being normal eyes (group N) and 66 eyes with primary congenital glaucoma (group G). Eyes of group G were grouped in eyes without perimetric changes and with early defects, characterized by MD > -6 dB (group G I= 41 eyes), and eyes with mild/advanced perimetric defects characterized by MD < or = -6 dB (group G II= 25 eyes). MAIN OUTCOME MEASURES reliability indices, global indices, GHT report, foveal threshold index and descriptive visual field defects. RESULTS The majority of patients showed good reliability. In group G I, 68% had normal visual fields; 22% showed localized defects and 10% showed general reduction of sensitivity. In group G II, 56% of the visual fields showed general reduction of sensitivity and 44% showed localized defects. The most common localized change was inferior paracentral scotoma. Eyes with normal visual fields in group G I had foveal threshold and MD values lower than normal eyes. The hemifield test was normal in 68% of eyes in group G I, and was abnormal in 100% of eyes in group G II. CONCLUSIONS Automated perimetry test was able to show typical defects of glaucoma contributing to initial evaluation and giving reliable parameters for the follow-up of eyes in patients with congenital glaucoma.
منابع مشابه
Motion automated perimetry identifies early glaucomatous field defects.
OBJECTIVE To determine if motion automated perimetry can identify early glaucomatous visual field defects in patients with suspected glaucoma (by disc), those with ocular hypertension, and those with primary open-angle glaucoma. METHODS Motion automated perimetry, a foveally centered motion test, and standard visual field tests were conducted on one randomly selected eye of normal patients (n...
متن کاملLong-term fluctuation in short-wavelength automated perimetry in glaucoma suspects and glaucoma patients.
PURPOSE To determine the magnitude of the homogeneous, LF(Ho), and the heterogeneous, LF(He), components of the long-term fluctuation (LF) in glaucoma suspects and in stable primary open angle glaucoma (POAG) patients undergoing short-wavelength automated perimetry (SWAP) and to compare the magnitude of the SWAP LF components with those elicited by standard white-on-white (W-W) perimetry. MET...
متن کاملA comparison of Goldmann and Humphrey automated perimetry in patients with glaucoma.
Humphrey automated threshold perimetry (Program 30-2) was performed on 42 eyes of 25 patients with glaucoma to determine both the sensitivity and specificity of automated perimetry in detecting glaucomatous visual field defects. Automated perimetry sensitivity was 90.38%, while automated perimetry specificity was 91%. Fifty-two patients and a technician took part in a survey to determine their ...
متن کاملInvestigating the effects of glaucomatous (POAG) damage on the mVEP parameters
Introduction: Glaucoma is considered as a major cause of irreversible vision loss, worldwide. Glaucoma includes a diverse ophthalmopathies characterized by attenuating the neural and connective tissue segments and eventually progression of specific patterns of visual dysfunction. Currently, perimetry is known as the most accurate diagnostic method in glaucoma and its follow up...
متن کاملComparison of visual evoked potentials, automated perimetry and frequency-doubling perimetry in early detection of glaucomatous visual field loss.
The present study compares frequency-doubling perimetry (FDP), automated perimetry (AP) and visual evoked potentials (VEP) for their ability to diagnose early glaucoma. In present study 224 patients of Clinic for Eye Diseases, Clinical Hospital "Sestre Milosrdnice" that had diagnosis of open angle glaucoma and glaucomatous visual field loss proven by automated static perimetry on only one eye w...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Arquivos brasileiros de oftalmologia
دوره 70 4 شماره
صفحات -
تاریخ انتشار 2007