Impact of Charge Degradation on the Life Cycle Climate Performance of a Residential Air- Conditioning System

نویسندگان

  • Mohamed Beshr
  • Vikrant Aute
  • Omar Abdelaziz
  • Brian Fricke
  • Reinhard Radermacher
  • Mohamed BESHR
  • Vikrant AUTE
  • Omar ABDELAZIZ
  • Brian FRICKE
  • Reinhard RADERMACHER
چکیده

Vapor compression systems continuously leak a small fraction of their refrigerant charge to the environment, whether during operation or servicing. As a result of the slow leak rate occurring during operation, the refrigerant charge decreases until the system is serviced and recharged. This charge degradation, after a certain limit, begins to have a detrimental effect on system capacity, energy consumption, and coefficient of performance (COP). This paper presents a literature review and a summary of previous experimental work on the effect of undercharging or charge degradation of different vapor compression systems, especially those without a receiver. These systems include residential air conditioning and heat pump systems utilizing different components and refrigerants, and water chiller systems. Most of these studies show similar trends for the effect of charge degradation on system performance. However, it is found that although much experimental work exists on the effect of charge degradation on system performance, no correlation or comparison between charge degradation and system performance yet exists. Thus, based on the literature review, three different correlations that characterize the effect of charge on system capacity and energy consumption are developed for different systems as follows: one for air-conditioning systems, one for vapor compression water-towater chiller systems, and one for heat pumps. These correlations can be implemented in vapor compression cycle simulation tools to obtain a better prediction of the system performance throughout its lifetime. In this paper, these correlations are implemented in an open source tool for life cycle climate performance (LCCP) based design of vapor compression systems. The LCCP of a residential air-source heat pump is evaluated using the tool and the effect of charge degradation on the results is studied. The heat pump is simulated using a validated component-based vapor compression system model and the LCCP results obtained using the three charge degradation correlations are compared.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Study of Thermostat Impact on Energy Consumption in a Residential Building by Using TRNSYS

The present study investigates the effectiveness of thermostat control strategy in cooling energy consumption in residential buildings. To evaluate the energy consumption, two scenarios including a residential zone with and without the thermostat control system are assumed. The TRNSYS software provides an efficient numerical tool to model and evaluate a cooling system. Furthermore, since solar-...

متن کامل

Passive Energy Air-to-Water Heat Pipe Based Heat Exchanger and its Potential of Air Pre-cooling in Air Conditioning Systems for Iran Climate

Air pre-cooling equipment is normally being employed in air-conditioning systems for pre-cooling the ambient outdoor air to enhance the air-conditioning systems performance. In this study, the potential of a passive water-to-air heat pipe based heat exchanger (HPHEX) for air pre-cooling purpose in air-conditioning systems for the high cooling load demanding regions of Iran was investigated. To ...

متن کامل

New Copper-based Heat Exchangers for Alternative Refrigerants

The ongoing global effort to replace current refrigerants with zero Ozone Depletion Potential (ODP) and virtually zero Global Warming Potential (GWP) refrigerants has important implications for heat exchangers, air conditioning system design, and the materials choices in these designs. Natural refrigerants with higher flammability, CO2, HFOs, and HFC – HFO blends each place different requiremen...

متن کامل

New High Performance, Low GWP Refrigerants for Stationary AC and Refrigeration

In response to concerns about global climate change, and in consideration of probable legislation that may impact the production and use of refrigerants with high global warming potential, a set of new refrigerant candidates has been developed for evaluation. Some candidates are designed for stationary air conditioning in residential and light commercial end uses. Other refrigerant candidates w...

متن کامل

Design and operation optimization of an air conditioning system through simulation: an hour-by-hour simulation study

In the present research, performance validation of a Heating, Ventilation, and Air Conditioning (HVAC) system operating in a library building was conducted. The operating HVAC system was studied in terms of the provided indoor air conditions and energy consumption level. The fieldwork measurements showed that the HVAC system is not capable of providing the desired indoor air conditions based on...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014