Biological, analytical and experimental components of variance in a long-term study of plasma constituents in rat.

نویسندگان

  • J Lindena
  • D Büttner
  • I Trautschold
چکیده

Statistical analysis of variance was applied to data from determinations of 14 plasma constituents in 25 rats in order to evaluate the analytical, experimental and biological (inter-and intraindividual) component of variance. Blood was taken seven times in intervals of 8-10 days, the last one by catheter technique and the other by heart puncture. The analytical portion of variance was determined by the concurrent analysis of a pool plasma standard. The experimental component of variance was evaluated by the comparison of the variation of the catheter values with that of the pooled data from heart puncture. The coefficient of variation for the latter may be grouped into three categories: less than 10% for protein, Na+, K+, Ca2+; 10-20% for urea, phosphate and the enzymes as alanine aminotransferase, choline esterase, alkaline phosphatase and leucine arylamidase and 20-65% for the other enzymes lactate dehydrogenase, malate dehydrogenase, aspartate aminotransferase and creatine kinase. The results from the samples taken by catheter technique generally revealed the lower values for the mean as well as for the variance. It became evident that the procedure of heart puncture is afflicted with the most aggravating interference factors, thus accounting for most of the experimental component of variance. The observed differences between the single blood drawings, the non-Gaussian distribution for several constituents, and the interactions between the components of variance do not always fit for the statistical concept of additivity of the single components.(ABSTRACT TRUNCATED AT 250 WORDS)

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Systematic analysis of main constituents in rat biological samples after oral administration of the methanol extract of Fructus Aurantii by HPLC-ESI-MS/MS

High performance liquid chromatography (HPLC) with diode array detection (DAD) and electrospray ionization tandem mass spectrometry (ESI/MS/MS) was used to analyze the main components in the methanol extract of Fructus Aurantii (FA) and the metabolites in rat biological samples after oral administration of the methanol extract of FA. There were 31 constituents identified in the extract of FA in...

متن کامل

Systematic analysis of main constituents in rat biological samples after oral administration of the methanol extract of Fructus Aurantii by HPLC-ESI-MS/MS

High performance liquid chromatography (HPLC) with diode array detection (DAD) and electrospray ionization tandem mass spectrometry (ESI/MS/MS) was used to analyze the main components in the methanol extract of Fructus Aurantii (FA) and the metabolites in rat biological samples after oral administration of the methanol extract of FA. There were 31 constituents identified in the extract of FA in...

متن کامل

Identification of chemical constituents in the extract and rat serum from Ziziphus jujuba Mill. by HPLC-PDA-ESI-MSn

Chinese jujube (Ziziphus jujuba Mill.) has long been widely used for human consumption and medicinal purposes in China. It has been reported to possess several vital biological activities. However, the systematic study on the chemical constituents absorbed into plasma and their metabolites is still insufficient. A high-performance liquid chromatography-photodiode array detector-electrospray ion...

متن کامل

Identification of chemical constituents in the extract and rat serum from Ziziphus jujuba Mill. by HPLC-PDA-ESI-MSn

Chinese jujube (Ziziphus jujuba Mill.) has long been widely used for human consumption and medicinal purposes in China. It has been reported to possess several vital biological activities. However, the systematic study on the chemical constituents absorbed into plasma and their metabolites is still insufficient. A high-performance liquid chromatography-photodiode array detector-electrospray ion...

متن کامل

P-7: Effects of Long-Term Exposure to Radiofrequency Radiations Emitted by Common Mobile Jammers on Sperm Quality Parameters in Rat

Background Exposure to electromagnetic fields (EMFs) by using electrical machines, tools, industrial instruments, power lines, and communications devices has occurred as a result of technological developments and is causing a threat to normal lives. The aim of this study was to evaluate the effects of long-term exposure to radiofrequency (RF) radiations emitted by mobile jammers.on sperm qualit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of clinical chemistry and clinical biochemistry. Zeitschrift fur klinische Chemie und klinische Biochemie

دوره 22 1  شماره 

صفحات  -

تاریخ انتشار 1984