Performance of semipermeable membrane devices for sampling of organic contaminants in groundwater.
نویسندگان
چکیده
Lipid-filled semipermeable membrane devices (SPMDs) are receiving increasing attention as passive, in situ samplers for the assessment of environmental pollutant exposure. Although SPMDs have been successfully used in a variety of field studies in surface waters, only a few studies have addressed their characteristics as groundwater samplers. In this study, the performance of the SPMDs for monitoring organic contaminants in groundwater was evaluated in a pilot field application in an area severely contaminated by chemical waste, especially by chlorinated hydrocarbons. The spatial distribution of hydrophobic groundwater contaminants was assessed using a combination of passive sampling with SPMDs and non-target semiquantitative GC-MS analysis. More than 100 contaminants were identified and semiquantitatively determined in SPMD samples. Along the 6 field sites under investigation, a large concentration gradient was observed, which confirms a very limited mobility of hydrophobic substances in dissolved form in the aquifer. The in situ extraction potential of the SPMD is limited by groundwater flow, when the exchange volume of well water during an exposure is lower than the SPMD clearance volume for the analytes. This study demonstrates that SPMDs present a useful tool for sampling and analyzing of groundwater polluted with complex mixtures of hydrophobic chemicals and provides guidance for further development of passive sampling technology for groundwater.
منابع مشابه
Use of triolein-semipermeable membrane devices to assess the bioconcentration and sediment sorption of hydrophobic organic contaminants in the Huaihe River, China.
Triolein-containing semipermeable membrane devices (triolein-SPMD) were deployed I m above the sediments at two sampling sites in the Huaihe River, China, for a period of 28 d. Sediment and fish samples were simultaneously collected from the same sampling sites. Concentrations of substituted benzenes, selected pesticides, polycyclic aromatic hydrocarbon (PAH), and polychlorinated biphenyls (PCB...
متن کاملApplication of passive sampling for measuring dissolved concentrations of organic contaminants in the water column at three marine superfund sites.
Currently, there is an effort under way to encourage remedial project managers at contaminated sites to use passive sampling to collect freely dissolved concentrations (Cfree ) of hydrophobic organic contaminants to improve site assessments. The objective of the present study was to evaluate the use of passive sampling for measuring water column Cfree for several hydrophobic organic contaminant...
متن کاملField uptake rates of hydrophobic organic contaminants by semipermeable membrane devices: environmental monitoring considerations.
The uptake rates of selected hydrophobic organic contaminants (HOCs) by semipermeable membrane devices (SPMDs)--a polyethylene layflat containing the lipid triolein--were investigated under natural conditions. SPMDs were exposed in three sampling sites (industrial, urban, and agricultural areas) in the Tajo River (Toledo, Spain) for 5, 11 and 20 d. The organochlorine compounds 4,4'-DDT, 4,4'-DD...
متن کاملShort-term exposure testing of six different passive samplers for the monitoring of hydrophobic contaminants in water.
Passive sampling devices are increasingly relied upon for monitoring non-polar organic contaminants in water. While many types of devices are available they have seldom been evaluated alongside each other. We tested six passive sampling devices namely: Chemcatcher, two modified versions of the membrane enclosed sorptive coating (MESCO I (m) and MESCO II), silicone rod and strip and semipermeabl...
متن کاملReview of the background and application of triolein-containing semipermeable membrane devices in aquatic environmental study.
This paper briefly reviews research on passive in situ samplers for aquatic environments but focuses on the development and application of the triolein-containing semipermeable membrane device in aquatic environmental monitoring. Special attention is paid to the calibration of the devices, quality control issues, and its potential uses in environmental assessments of aquatic contaminants. Also,...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of environmental monitoring : JEM
دوره 7 5 شماره
صفحات -
تاریخ انتشار 2005