Evaluation of a cellulose-acetate electrophoresis system for serum protein fractionation.

نویسندگان

  • A Kaplan
  • J Savory
چکیده

A rapid system for the quantitative fractionation of serum proteins by electrophoresis on cellulose-acetate membranes was evaluated and found to be quite precise. The reproducibility (coefficient of variation) of the routine fractionation of a control serum carried out 40 times during a 15-week period was 2.4% for albumin and 14.2, 6.0, 6.1, and 5.2%, respectively, for the ar-, a2-, /3-, and -y-globulin fractions. Normal values are given for serum protein fractions (specimens from nonprofessional blood donors) obtained by cellulose acetate electrophoresis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Detection of cryoglobulins in serum of Caspian miniature horse

Blood samples were collected from 20 healthy miniature Caspian horses at 37 °C. Isolation of cryoglobulin was performed based on a standard method in present study. Harvested sera were kept at 4 °C for two hours and then examined for cryoglubolin. Four serum samples containing precipitate Suspicious of containing cryoglobulin were selected. Subsequently serum protein electrophoresis was perform...

متن کامل

Serum protein fractions as determined by cellulose actate electrophoresis in schistosoma mattheei infested sheep.

VAN ZYL, LULU C. , 1974. Serum protein fractions as determined by cellulose acetate electrophoresis in Schistosoma mattheei infested sheep. Onderstepoort J. vet . Res. 41, 714 (1974). The serum protein fraction values of Dorper sheep infested with Schistosoma mattheei were determined by cellulose acetate electrophoresis at regular intervals for 15 months. Statistical analyses showed that increa...

متن کامل

Rapid cellulose acetate electrophoresis. I. Serum proteins.

A method of electrophoresis utilizing cellulose acetate is described wherein quantitation of serum protein fractions by densitometry is accomplished within 2 hr. of initiation of the procedure. The densitometer was found to have a linear response to amido black dye. Albumin and y-globulin demonstrated equal dye-binding characteristics. Combined with the absence of albumin trailing, this has aff...

متن کامل

Imprecision of quantification of serum protein fractions by electrophoresis on cellulose acetate.

We studied the precision of densitometric quantification of the protein zones resolved by cellulose acetate electrophoresis. Replicate analyses of patients' samples by a single technologist showed mean CVs ranging from 2.9% for serum albumin to 9.5% for alpha 1-globulin. There were marked differences in measurements obtained by replicate analysis of the same samples by two experienced technolog...

متن کامل

Serum Alpha-1-antitrypsin Evaluation by Three Electrophoretic, Enzymatic and Immunodiffussion Methods

Abstract Background & Objective: Alpha-1-antitrypsin (AAT) is the major component of the human plasma alpha-1 globulin proteins and acts as a major inhibitor of proteolytic enzymes, particularly elastase. AAT deficiency is accompanied by lung, liver and other disorders, therefore, AAT is clinically important and its precise evaluation is diagnostically critical. In present study serum AAT was e...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 11 10  شماره 

صفحات  -

تاریخ انتشار 1965