A viscoelastic model of shear-induced hemolysis in laminar flow.
نویسندگان
چکیده
We present measurements of human blood hemolysis caused by laminar shear stresses ranging from 50 to 500 Pa for exposure times extending from 60 to 300 s using a Taylor-Couette device. A viscoelastic model is proposed that captures the response of the red blood cells to shear stress. The model is based on well-established mechanical properties of the red blood cell membrane, and shows good agreement with data from the experiments presented here, as well as data from the existing literature. Two characteristic time scales are identified: a fast time scale corresponding to the relaxation time of the red blood cell membrane and a slow time scale that represents the onset of plasticity and is related to hemoglobin release from a damaged cell. The model proposed here collapses the available data over almost five orders of magnitude in exposure time and shear stresses up to 500 Pa.
منابع مشابه
Numerical Simulation of Separation Bubble on Elliptic Cylinders Using Three-equation k-? Turbulence Model
Occurrence of laminar separation bubbles on solid walls of an elliptic cylinder has been simulated using a recently developed transitional model for boundary layer flows. Computational method is based on the solution of the Reynolds averaged Navier-Stokes (RANS) equations and the eddy-viscosity concept. Transitional model tries to simulate streamwise fluctuations, induced by freestream turbulen...
متن کاملParametric study of a viscoelastic RANS turbulence model in the fully developed channel flow
One of the newest of viscoelastic RANS turbulence models for drag reducing channel flow with polymer additives is studied in different flow and rheological properties. In this model, finitely extensible nonlinear elastic-Peterlin (FENE-P) constitutive model is used to describe the viscoelastic effect of polymer solution and turbulence model is developed in the k-ϵ-(ν^2 ) ̅-f framework. The geome...
متن کاملA strain-based flow-induced hemolysis prediction model calibrated by in vitro erythrocyte deformation measurements.
Hemolysis is caused by fluid stresses in flows within hypodermic needles, blood pumps, artificial hearts, and other cardiovascular devices. Developers of cardiovascular devices may expend considerable time and effort in testing of prototypes, because there is currently insufficient understanding of how flow-induced cell damage occurs to accurately predict hemolysis. The objective of this projec...
متن کاملNumerical simulation of nanofluid flow over diamond-shaped elements in tandem in laminar and turbulent flow
In this paper, the Al2O3-water nanofluid flow in laminar and turbulent flows inside tubes fitted with diamond-shaped turbulators is numerically modeled. The nanofluid flow is modeled by employing a two-phase mixture method and applying the constant heat flux boundary condition at tube walls. In the results, the effects of different parameters such as the geometry of turbulators, volume fraction...
متن کاملA Study of Flow Properties of Kuwaiti Crude Oil Obtained from Different Sources
The rheological properties of four different Kuwaiti crude oils in the presence of polyacrylamide (PAA) were investigated. PAA was varied at three different concentrations of 25, 50, and 75 ppm to study the viscoelastic properties in the untreated samples. Four different temperatures (25, 30, 35, and 40 °C) were used to evaluate different viscoelastic parameters of the treated and untreated Kuw...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Biorheology
دوره 50 1-2 شماره
صفحات -
تاریخ انتشار 2013