Skin-fixed scapula trackers: a comparison of two dynamic methods across a range of calibration positions.
نویسندگان
چکیده
The aim of this study was to establish the optimal methodology for skin-fixed measurement of the scapula during dynamic movement. This was achieved by comparing an optimally positioned Scapula Tracker device (ST) to a previously described palpation device, taken as the true measure of scapular kinematics. These measurements were compared across a range of calibration positions, including the use of multiple calibration positions for a single movement, in order to establish an optimal calibration approach. Ten subjects' scapular motion was measured using this ST and a previously described Acromial Method (AM). The two datasets were compared at a standard, an optimal and a 'multiple' calibration position, thus allowing a direct comparison between two common skin-fixed methods to track the bony kinematics of the scapula across different calibration positions. A comparison was also made with a bone-fixed technique from the literature. At both the standard and optimal calibration positions the ST was shown to be the more accurate measure of internal rotation and posterior tilt, particularly above 100° of humerothoracic elevation. The ST errors were found to be acceptable in relation to clinically important levels. Calibration positions have been shown to have a significant effect on the errors of both skin-fixed measurement techniques and therefore the importance of correct calibration is highlighted. It has thus been shown that a ST can be used to accurately quantify scapular motion when appropriately calibrated for the range of motion being measured.
منابع مشابه
Effects of attachment position and shoulder orientation during calibration on the accuracy of the acromial tracker.
The acromial tracker is used to measure scapular rotations during dynamic movements. The method has low accuracy in high elevations and is sensitive to its attachment location on the acromion. The aim of this study was to investigate the effect of the attachment position and shoulder orientation during calibration on the tracker accuracy. The tracker was attached to one of three positions: near...
متن کاملComparison between tripod and skin-fixed recording of scapular motion.
Non-invasive dynamical measurements of 3D scapular motion can be performed easily by attachment of a 6 DOF electromagnetic receiver onto the skin above the acromion. To quantify the introduction of possible errors due to skin displacement, we assessed 3D scapular positions on n=8 subjects by both tripod and skin-fixed method. Error analysis included the variables method (tripod, skin-fixed simu...
متن کاملComparison of the Obtained Results from Two Calibration Methods in MRI Brachytherapy Normoxic Polymer Gel Dosimetry
Introduction: Despite the fact that the clinical implementation of polymer gel dosimetry has been facilitated after the introduction of normoxic gels, there are still complications in its clinical routine use that are under investigation. In the current work, the feasibility of using a normoxic polymer gel dosimeter named MAGICA has been investigated for use in our clinical brachytherapy applic...
متن کاملآشکارسازی پویای پوست با استفاده از ادغام ویژگیهای مبتنی بر هیستوگرام دو بعدی
This paper presents a dynamic approach to Skin Detection- to separate the skin pixels from non-skin pixels- in colored images. The static methods which use a fixed skin color model, will fail if there are illumination variations or different skin colors in an image. Because of contextual information the proposed algorithm will be less sensitive to the uncontrolled illumination conditions. In ad...
متن کاملComparison of Functional Stability of Shoulder Girdle between Individuals with Symmetric and Asymmetric Scapula
Background and Aim: Changes in the position of the scapula due to its multiple roles, including acting as a muscle binding site and stabilization in this area can reduce the physiological and biomechanical efficiency of the shoulder, which ultimately increases shoulder injury. Therefore, the purpose of this study was to compare the functional stability of shoulder girdle between asymmetric and ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of biomechanics
دوره 44 10 شماره
صفحات -
تاریخ انتشار 2011