An evaluation of the JPL TOPSAR for extracting tree heights

نویسندگان

  • Yutaka Kobayashi
  • Kamal Sarabandi
  • Leland E. Pierce
  • M. Craig Dobson
چکیده

In this paper, the accuracy of the digital elevation model (DEM) generated by the Jet Propulsion Laboratory (JPL) TOPSAR for extracting canopy height is evaluated. For this purpose, an experiment using C-band TOPSAR at the Michigan Forest Test Site (MFTS) in Michigan’s Upper Peninsula was conducted. Nearly 25 forest stands were chosen in MFTS, which included a variety of tree types, tree heights, and densities. For these stands, extensive ground data were also collected. The most important and difficult-to-characterize ground truth parameter was the forest ground level data, which is required for extracting the height of the scattering phase center from the interferometric SAR(INSAR) DEM. To accomplish this, differential global positioning system (GPS) measurements were done to accurately ( 5 cm) characterize the elevation of: 1) a grid of points over the forest floor of each stand and 2) numerous ground control points (GCPs) over unvegetated areas. Significant discrepancies between GPS and TOPSAR DEM and between the two TOPSAR DEMs of the same area were observed. The discrepancies are attributed to uncompensated aircraft roll and multipath. An algorithm is developed to remove the residual errors in roll angle using elevation data from: 1) 100-m resolution U.S. Geological Survey DEM and 2) the GPS-measured GCPs. With this algorithm, the uncertainties are reduced to within 3 m. Still, comparison between the corrected TOPSAR DEMs shows an average periodic height discrepancy along the cross-track direction of about 5 m. Simulation results show that this might have been caused by multipath from an object near one of the INSAR antennas. Careful examination of the coherence image and the backscatter image also show such periodic patterns. Recommendations are provided for the extraction of the best estimate of the scattering phase center height, and a model is provided to estimate actual tree height. It is accurate to within 1 m or 10% for the red pine test stands used here.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analysis and evaluation of the NASA/JPL TOPSAR across-track interferometric SAR system

We have evaluated the accuracy of digital elevation models (DEMs) generated by the JPL/NASA TOPSAR synthetic aperture radar interferometer instrument by acquiring topographic data in the summer of 1992 over the National Training Center, Ft. Irwin, California, a desert area with significant relief and varied terrain, and comparing the measurements to a very accurate digital elevation model deriv...

متن کامل

Detection and extraction of buildings from interferometric SAR data

In this paper we present a complete procedure for the extraction and characterization of building structures starting from the three-dimensional (terrain elevation) data provided by interferometric SAR measurements. Each building is detected and isolated from the surroundings by means of a suitably modified machine vision approach, originally developed for range image segmentation. The procedur...

متن کامل

The Data Calibration of the AIRSAR PacRim II Mission

In this paper, we present the calibration results of the NASA/JPL Airborne Synthetic Aperture Radar (AIRSAR) for the Pacific Rim II mission. We also demonstrate the key elements of the calibration techniques for both polarimetric SAR (POLSAR) and cross-track interferometric SAR (TOPSAR) processed with the AIRSAR Integrated Processor.

متن کامل

Multiscale Fusion of Insar Data for Hydrological Applications

Accurate determination of topography is required for a wide range of civilian and governmental applications. For example, modeling flood extent, flow velocity, and sediment transport associated with river networks requires bare-surface elevations with sub-meter height accuracy and spatial resolutions better than 10 meters. Strip-map interferometric synthetic aperture radar (INSAR) sensors have ...

متن کامل

Simulation of interferometric SAR response for characterizing the scattering phase center statistics of forest canopies

A coherent scattering model for tree canopies is employed in order to characterize the sensitivity of an interferometric SAR (INSAR) response to the physical parameters of forest stands. The concept of an equivalent scatterer for a collection of scatterers within a pixel, representing the vegetation particles of tree structures, is used for identifying the scattering phase center of the pixel w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • IEEE Trans. Geoscience and Remote Sensing

دوره 38  شماره 

صفحات  -

تاریخ انتشار 2000