Effect of output variation with dose rate on the Virtual Wedge factor

نویسندگان

  • X. Ronald Zhu
  • Michael T. Gillin
چکیده

Siemens Virtual Wedge factor may drift significantly due to increase in output as dose rate decreases. This variation of output is caused by defective sample and hold boards in the dosimetry circuit due to radiation damage. In this note, we present a simple model based on the principle of Virtual Wedge operation and the measured output variation with dose rate to quantitatively describe Virtual Wedge factor drift as a function of field size and wedge angle. Our results support the recommendation that VWF be measured for large field sizes (e.g., 20 ' 20 cm2) and large wedge angles (e.g., 60 degrees) as a part of routine quality assurance.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Interpretation of In-air Output Ratio of Wedged Fields in Different Measurement Conditions

Introduction: The head scatter factor (Sc) is one of the important parameters for monitor unit (MU) calculation. There are multiple factors that impact the Sc values, such as, head structures, back scattering in to dose monitoring chambers, wedges and so on. This study aimed to investigate the variations of SC with different build-up cap materials, wall thickness, Source to ...

متن کامل

Evaluation of Three-dimensional Treatment Planning System (TPS) performance in dose calculation of virtual wedged fields using film dosimetry

Introduction: Nowadays radiotherapy plays an important role in cancer treatment. Different radiotherapy techniques improvement emphasizes on using of the precise ، appropriate and useful algorithms. one of these techniques are wedged which is used in radiotherapy to compensate missing tissues and create a uniform dose distribution in tissues. The Siemens Artiste linear accelera...

متن کامل

Assessment of variation of wedge factor with depth, field size and SSD for Neptun 10PC Linac in Mashhad Imam Reza Hospital

Background: In radiotherapy, wedge filters are used for optimizing the tumor dose distribution in patients. The attenuation in beam intensity due to the presence of wedge filter is compensated by means of a wedge factor measured at the central axis of the beam. The field size, depth and SSD dependence of wedge factor have been assessed for 9MV radiations of Neptun PC linear accelerator. Materia...

متن کامل

Characterization of Wedge Factors and Dose Distributions in Radiotherapy with Symmetric and Asymmetric Physical Wedged Beams of 6 MV Photon Beam

Introduction: Physical wedge by modify photon beam shape and intensity has been utilized in radiotherapy to obtain uniformly dose distribution in tumor site with reduced hot spots. Calculation of dosimetric parameters for both symmetric and asymmetric wedged fields is proved necessary during linear accelerator (Linac) commissioning. The present study aimed to achieve o...

متن کامل

Investigation of the Field Size Effect on Wedge Field Isodose Curves Angle for Two Energies; 6 & 18 MV, produced by VARIAN 2100C Linac

Introduction: Nowadays,  considerable developments  in  the field  of  radiotherapy have  been  achieved.  They  include  the  advances  made  in  the  equipments  and  treatment  planning  techniques  which  require  highly complex calculations. Such achievements have made it possible to treat cancer patients not only  with  higher  radiation  dose  but  also  with  higher  precision  and  con...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2008