Effect of output variation with dose rate on the Virtual Wedge factor
نویسندگان
چکیده
Siemens Virtual Wedge factor may drift significantly due to increase in output as dose rate decreases. This variation of output is caused by defective sample and hold boards in the dosimetry circuit due to radiation damage. In this note, we present a simple model based on the principle of Virtual Wedge operation and the measured output variation with dose rate to quantitatively describe Virtual Wedge factor drift as a function of field size and wedge angle. Our results support the recommendation that VWF be measured for large field sizes (e.g., 20 ' 20 cm2) and large wedge angles (e.g., 60 degrees) as a part of routine quality assurance.
منابع مشابه
Interpretation of In-air Output Ratio of Wedged Fields in Different Measurement Conditions
Introduction: The head scatter factor (Sc) is one of the important parameters for monitor unit (MU) calculation. There are multiple factors that impact the Sc values, such as, head structures, back scattering in to dose monitoring chambers, wedges and so on. This study aimed to investigate the variations of SC with different build-up cap materials, wall thickness, Source to ...
متن کاملEvaluation of Three-dimensional Treatment Planning System (TPS) performance in dose calculation of virtual wedged fields using film dosimetry
Introduction: Nowadays radiotherapy plays an important role in cancer treatment. Different radiotherapy techniques improvement emphasizes on using of the precise ، appropriate and useful algorithms. one of these techniques are wedged which is used in radiotherapy to compensate missing tissues and create a uniform dose distribution in tissues. The Siemens Artiste linear accelera...
متن کاملAssessment of variation of wedge factor with depth, field size and SSD for Neptun 10PC Linac in Mashhad Imam Reza Hospital
Background: In radiotherapy, wedge filters are used for optimizing the tumor dose distribution in patients. The attenuation in beam intensity due to the presence of wedge filter is compensated by means of a wedge factor measured at the central axis of the beam. The field size, depth and SSD dependence of wedge factor have been assessed for 9MV radiations of Neptun PC linear accelerator. Materia...
متن کاملCharacterization of Wedge Factors and Dose Distributions in Radiotherapy with Symmetric and Asymmetric Physical Wedged Beams of 6 MV Photon Beam
Introduction: Physical wedge by modify photon beam shape and intensity has been utilized in radiotherapy to obtain uniformly dose distribution in tumor site with reduced hot spots. Calculation of dosimetric parameters for both symmetric and asymmetric wedged fields is proved necessary during linear accelerator (Linac) commissioning. The present study aimed to achieve o...
متن کاملInvestigation of the Field Size Effect on Wedge Field Isodose Curves Angle for Two Energies; 6 & 18 MV, produced by VARIAN 2100C Linac
Introduction: Nowadays, considerable developments in the field of radiotherapy have been achieved. They include the advances made in the equipments and treatment planning techniques which require highly complex calculations. Such achievements have made it possible to treat cancer patients not only with higher radiation dose but also with higher precision and con...
متن کامل