Risk factors associated with early implant failure: A 5-year retrospective clinical study.
نویسندگان
چکیده
STATEMENT OF PROBLEM The replacement of lost teeth with dental implants is a widespread treatment whose associated problems are also frequently encountered. Nevertheless, the factors associated with early implant failure have not been well documented. Further analyses of the factors influencing osseointegration establishment are required to maximize the predictability of the procedure and minimize implant failures. PURPOSE The purpose of this retrospective clinical study was to explore the association between possible risk factors and early implant failure. MATERIAL AND METHODS This retrospective clinical study evaluated 142 participants who received 276 external connection BTI implants between 2007 and 2011. Participant variables (age, sex, systemic disease, tobacco use, alcohol consumption, bruxism, and degree of periodontal disease), implant variables (type of edentulism, localization, area, diameter, length, and bone quality), intervention variables (expansion mechanisms, sinus augmentation techniques, bone regeneration, and implant insertion), and postoperative variables (presence of pain/inflammation at 1 week postsurgery) were studied. A multilevel logistic regression model (mixed effects-type model) was used to determine the influence of variables on early implant failure. RESULTS Early implant failure was significantly associated with the male sex (P=.001), severe periodontal disease (P=.005), short implants (P=.001), expansion technique (P=.002), and postoperative pain/inflammation at 1 week postsurgery (P<.001). CONCLUSIONS Early dental implant failure is more frequent in men and in individuals with severe periodontal disease, short implants, pain/inflammation at 1 week postsurgery, or bone expansion treatment.
منابع مشابه
Risk Factors and Early Survival Rate of Biomet 3i Dental Implants. A Retrospective Study
Introdouction: Although highly desirable outcomes and longterm survival of dental implant treatments are well documented, implant failures still occur due to various reasons. Several risk factors may impair implant survival including implant dimensions (length, diameter, and implant design), procedures, local bone density at the implant site, and patient-related risk factors such as age, smokin...
متن کاملUnplanned Operations and Adverse Events after Surgery for Diaphyseal Fracture of the Clavicle
Background: We used a database of patients treated at three hospitals to study the primary null hypothesis that thereare no factors associated with unplanned reoperations or adverse events after surgical repair for diaphyseal claviclefracture. Additionally we addressed the following secondary study questions: 1. What is the prevalence of unplannedreoperations or adverse events...
متن کاملCumulative survival rate and associated risk factors of Implantium implants: A 10-year retrospective clinical study
PURPOSE The objective of this study was to determine the cumulative survival rate (CSR) and associated risk factors of Implantium implants by retrospective clinical study. MATERIALS AND METHODS Patients who received Implantium implants (Dentium Co., Seoul, Korea) at Korea University Guro Hospital from 2004 to 2011 were included. The period between the first surgery and the last hospital visit...
متن کاملبررسی عوامل مؤثر بر زمان شکست ایمپلنت با استفاده از مدل رگرسیون خطرات متناسب کاکس
Background and Aims: In recent years, dental implants have received special attention in dentistry. Due to the remarkable success of predictable dental implants, there is growing interests in the scientific community from descriptions of implant success toward identify factors associated with implant failure. The purpose of this study was to identify the risk factors associated with implant f...
متن کاملAnalysis of incidence and associated factors with fractured implants: a retrospective study.
Osseointegrated threaded titanium screw-type implants rarely lose integration after the first year of clinical function. Implant failure can occur for other reasons, with implant fracture being one of the major reasons for late failure. The purpose of the present study was to determine the incidence of implant fracture in completely edentulous and partially edentulous arches and to determine wh...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of prosthetic dentistry
دوره 115 2 شماره
صفحات -
تاریخ انتشار 2016